7. Thread the strainer into the drain adapter. Tighten the
connection to create a watertight seal.
8. Attach one end of the 3/4 inch exible drain hose to
the 3/4 inch barbed drain adapter connection using the
supplied hose clamp. The supplied exible drain is 13
inches long. If a longer drain hose is required, it must
be installer-supplied.
9. Route the drain hose through the lter box and attach
the other end to the p-trap drain adapter using a hose
clamp. The drain adapter is designed to be glued into
a 1-1/4 inch PVC pipe.
10. Connect the drain adapter into the household waste
drain pipe.
If the p-trap is located inside a sealed walled, it must
have permanently-glued joints. If the p-trap is in an
accessible location, a standard non-glued p-trap is
acceptable.
Note: Whichever installation method is used, it must
meet local standards and building codes.
4.7 Remote Filter Location
The lter unit can also be installed remotely, up to 15 feet
away from the water dispenser. The remote lter location
is normally associated with the installation of a water
chiller.
1. If desired, remove the lter unit from the lter box.
2. Securely mount the lter unit in the desired location.