7. Thread the strainer into the drain adapter. Tighten the
connection to create a watertight seal.
8. Attach one end of the 3/4 inch exible drain hose to
the 3/4 inch barbed drain adapter connection using the
supplied hose clamp. The supplied exible drain is 13
inches long. If a longer drain hose is required, it must
be installer-supplied.
9. Route the drain hose through the lter box and attach
the other end to the p-trap drain adapter using a hose
clamp. The drain adapter is designed to be glued into
a 1-1/4 inch PVC pipe.
10. Connect the drain adapter into the household waste
drain pipe.
If the p-trap is located inside a sealed walled, it must
have permanently-glued joints. If the p-trap is in an
accessible location, a standard non-glued p-trap is
acceptable.
Note: Whichever installation method is used, it must
meet local standards and building codes.
4.7 Remote Filter Location
The lter unit can also be installed remotely, up to 15 feet
away from the water dispenser. The remote lter location
is normally associated with the installation of a water
chiller.
1. If desired, remove the lter unit from the lter box.
2. Securely mount the lter unit in the desired location.