3.5 Adjustment of minimum
level
WARNING!
Information for authorised
installer only.
To adjust the minimum level of the
burners:
1. Light the burner.
2. Turn the knob on the minimum
position.
3. Remove the knob and using thin
screwdriver lift up and remove the
plastic magnet holder.
4. With a thin screwdriver, adjust the
bypass screw position (A).
A
5. If you change:
from natural gas G20 20 mbar to
liquid gas, fully tighten the bypass
screw in.
from liquid gas to natural gas G20
20 mbar, undo the bypass screw
approximately 1/4 of a turn (1/2 of
a turn for Multi Crown burner).
6. Reassemble the magnet holder and
the knob.
WARNING!
Make sure the flame does
not go out when you quickly
turn the knob from the
maximum position to the
minimum position.
3.6 Electrical connection
Do not pull the mains cable to
disconnect the appliance. Always pull
the mains plug (if applicable).
The appliance must not be connected
with an extension cable, an adapter or
a multiple socket. There is a risk of
fire.
Do not let the power cable to heat up
to a temperature of more than 90° C.
The cable should be guided by means
of clamps fixed to the side of the
cabinet, in order to avoid any contact
with the appliance beneath the
cooktop.
Make sure that there is access to the
mains plug after the installation.
If the pilot lights turn on after
connecting the hob to the
mains, turn on and off the
control knob and wait until
the residual heat indicator
goes out.
Electrical Requirements
Permanent electrical installation must
agree with the latest I.E.E. Regulations
and local Electricity Board regulations.
For your own safety the installation must
be done by a qualified electrician (e.g.
your local Electricity Board, or a
www.aeg.com10