Service and Adjustment (cont'd)
Thermostats
The thermostat(s) of this water heater have been factory set at
their !owest position which approximates 120°F (Hot) to reduce
the risk of scald injury.
The upper thermostat (dual element models only) is not
adjustable. Its temperature setting is fixed to approximate 120°F
(Hot).
(DUAL ELEMENT MODELS ONLY)
UPPER THERMOSTAT NOT ADJUSTABLE
BEHIND UPPER ACCESS PANEL
The lower thermostat is factory set at its lowest position which
approximates 120°F (Hot) and is adjustable if a different water
temperature is desired. Read all warnings in this manual and on
the water heater before proceeding.
111
Temperature Settings
HOT-Is a thermostat setting of approximately 120°F,
which will supply hot water at the most economi-
ca] temperatures.
A-Is a thermostat setting of approximately 130°E
B-Is a thermostat setting of approximately 140°F.
This is the lowest setting for supply of hot water
to dishwashers.
C-Is a thermostat setting of approximately 150°E
VERY HOT-Is a thermostat settingof approximately 160°E It is
recommended that the dial be set lower whenever
possible.
Thermostat Adjustment
The upper and lower thermostats have been factory set at hot
(approximately 120°F) to reduce the risk of scald injury.
The upper thermostat (dual element models only) is not
adjustable. The lower thermostat is adjustable ifa different water
temperature is desired. Read all warnings in the "Temperature-
Regulation" section before proceeding.
The adjustment dial can be turned clockwise (__.J) to
increase the temperature setting or counter clockwise
_.._) to decrease the temperature setting.
LOWER THERMOSTATADJUSTABLE
THROUGH LOWER ACCESSPANEL