CAUTION
WARNING
To prevent electric shock, discon-
nect electrical power supply to
dishwasher before changing
panels. Do not operate dishwasher
while changing panels or when
lower access panel assembly is removed.
Tools and Materials required:
• 1/4" socket driver
• Phillips screwdriver
• Electric drill
• 1/8" and 3/16" drill bits
• Carpenters square
• Safety Glasses
The GPF475 Trim Kit provides for the installa-
tion of 3/4" thick custom door and access
panels with a typical 4" high toekick.
This Kit includes:
• Door panel support
• 5, 5/8" phillips flat head screws
• 3 round head screws
• GPF100 spring kit.
• Cut the 3/4" thick door panel to the
dimensions shown.
• Rout the bottom edge of the door panel on
the appearance side, 1/2" deep and 1-1/2"
high resulting in 1/4" thickness. See
illustration.
• The access panel height may be 3-3/4" to
4-1/4" max. The access panel height can
vary depending upon toekick height and
adjustments made to the leveling legs.
The custom panels should be constructed in
the same manner as cabinet doors. Cut edges
can be seen and must be finished for the best
appearance.
Step 1:
Cut 3/4" Thick
Custom Panels
1-1/2"
3/4"
1/2"
19-7/8"
23-5/8"
3/4" Thick Panel
Appearance Side
A*
23-5/8"
3/4" Thick Access Panel
*3-3/4" min., 4-1/4" max. for typical 4" toekicks.
Note:
The custom wood access panel should evenly match the
bottom of adjacent cabinets. Adjustments made to the leveling
legs to obtain correct height can affect the vertical dimension
(height) of the access panel.