Ashley DVAG17N 17,000 BTU Direct Vent Natural Gas Wall Heater

User Manual - Page 6

For DVAG17N.

PDF File Manual, 44 pages, Download pdf file

Loading ...
Loading ...
Loading ...
6
© 2021 United States Stove Company
INSTALLATION
INSTALLATION ITEMS
Before installing heater, make sure you have the
items listed below.
Piping (check local codes)
Sealant (resistant to propane gas)
Manual shutoff valve
Ground joint union
Sediment trap
Tee joint
Pipe wrench
The installation location shall provide the following:
a. Adequate combustion and ventilation air, and
b. Adequate accessibility clearances for servicing.
Minimum Clearance From Combustible
Construction
Rear
0.25 inches (with supplied
spacers)
Sides 6 inches
Top 36 inches
Floor 6 inches
Figure 4
CEILING
36”
(914 mm) Min.
6
(152 mm) Min.
6
(152 mm) Min.
FLOOR
PRODUCT FEATURES
Model No.
Input Power *
Btu/Hr. (kW)
Max. Gas Inlet
Pressure inch
W.C. (mm. W.C.)
Min. Gas Inlet
Pressure inch
W.C. (mm. W.C.)
Pres. Reg. Settings
Manifold inch W.C.
(mm. W.C.)
Valve Type
DVAG 11N 11,000 (3.20 kW) 10.5 (267 mm) 7 (178 mm) 5 (127 mm) Chant RTZ-WK
DVAG 11L 11,000 (3.20 kW) 14 (355 mm) 11 (280 mm) 10 (254 mm) Chant RTZ-WK
DVAG 17N 17,000 (4.94 kW) 10.5 (267 mm) 7 (178 mm) 5 (127 mm) Chant RTZ-WK
DVAG 17L 17,000 (4.94 kW) 14 (355 mm) 11 (280 mm) 10 (254 mm) Chant RTZ-WK
DVAG 30N 25,000 (7.33 kW) 10.5 (267 mm) 7 (178 mm) 5 (127 mm) Chant RTZ-WK
DVAG 30L 25,000 (7.33 kW) 14 (355 mm) 11 (280 mm) 10 (254 mm) Chant RTZ-WK
**NOTE: Minimum Gas Inlet Pressure for purpose of input adjustment. The efciency rating of the
appliance is a product thermal efciency rating determined under continuous operating conditions and
was determined independently of any installed system.