aus Installation and connection
44
Drinking water connection
1. Fasten the drinking water connection
to the tap according
to the installation instructions using
the enclosed parts.
Ensure that the drinking water
connection is not kinked, crushed
or twisted.
2. When replacing the appliance,
always use a new water supply
hose.
Water pressure:
at least 0.05 MPa (0.5 bar), maximum 1
MPa (10 bar).
At a higher water pressure:
connect pressure-reducing valve ahead.
Inlet rate:
minimum 10 litres/minute
Water temperature:
cold water.
Hot water:
Maximum temperature 60 °C.
Hot water connection *
Ho t wa t e r connect i on
* depending on the features of your
dishwasher
The dishwasher can be connected to
cold or hot water up to max. 60°C.
Connection to hot water is
recommended if the hot water can be
supplied by energetically favourable
means and from a suitable installation,
e.g. solar heating system with
circulation line. This will save energy
and time. The “Hot water” setting allows
you to adjust your dishwasher optimally
to operate with hot water. It is
recommended to have a water
temperature (temperature of the
incoming water) of at least 40 °C and
no more than 60 °C. It is not
recommended to connect the appliance
to hot water if the water is supplied from
an electric boiler.
Here’s how to change the hot water
setting:
1. Switch on ON/OFF switch (.
2. Press and hold the button
for 3 seconds.
The value §:... and will appear in
the display window h.
3. Press the button repeatedly
until the factory setting value :‹‹
appears in the display window h.
4. Adjust the setting using the buttons
+ and - H.
5. Press and hold the button
for 3 seconds.
The chosen setting has now been
stored in your dishwasher.
Electrical connection
Connect the appliance to an
alternating current only, ranging from
220 V to 240 V and 50 Hz or 60 Hz
via a correctly installed socket with
protective earth conductor. See
rating plate for required fusing 92.
The socket must be near the
appliance and freely accessible
following installation.
If the plug is not freely accessible, an
allpole disconnector with a contact
opening of at least 3 mm must be
fitted on the installation side to
satisfy the relevant safety
instructions.
The connection may be modified
by technicians only.
A power cord extension may be
purchased from customer service
only.
Use only a residual current operated
circuit-breaker which features the
symbol . Only this extension
guarantees compliance with
the currently valid regulations.
The appliance features a water
damage protection system. Please
note the system will function only
when the power supply
is connected.