EN
PORTABLE AIR CONDITIONER WI-FI
Translation of the original manual
SAC MT9030C / SAC MT9031C

SAC MT9030C / SAC MT9031C

A
1
2
3
4
5
6
8
9
7
10
11
B
1
2
3
4
5

C
2
3 4
5
6
W
7
8910
11
12
13
D
1
4
2
7
5
6
3
8
9
10
E

- 1 -
Revision 12/2021
Copyright © 2021, Fast ČR, a.s.
EN Portable Air Conditioner Wi-Fi
Important safety instructions
READ CAREFULLY AND STORE FOR FUTURE USE.
This symbol indicates that not adhering to
instructions may result in death or serious
injur ies.
WARNING :
To prevent the death or injury of the user or
other persons or damage to property, the
following instructions must be adhered to.
Incorrect use as aresult of not adhering to
instructions may cause death, injuries or
damage.
• This appliance may be used by children 8 years of
age and older and by persons with physical, sensory,
or mental impairments or by persons with alack of
experience or knowledge, if they are properly supervised
or have been informed about how to use the product in
asafe manner and understand the potential dangers.
• Cleaning and maintenance performed by the user must
not be performed by unsupervised children.
• Children must not play with the appliance.

- 2 -
Revision 12/2021
Copyright © 2021, Fast ČR, a.s.
• If the power cord is damaged, it must be replaced by an
authorised service centre or by another similarly qualified
person, this will prevent the creation of adangerous
situation. It is forbidden to use the appliance if it has
adamaged power cord.
• The appliance must be stored in amanner that prevents its
mechanical damage.
• The appliance must be stored in awell-ventilated location,
where the dimensions of the room correspond to the
dimensions specified for its operation.
• The appliance must be stored in aroom where an
open flame is not continuously in use (e.g. running gas
appliance) or where there are not sources of ignition (e.g.
running electrical heating element).
• Before connecting the appliance to apower socket, check
that the rated voltage on its rating label matches the
electrical voltage in the power socket.
• Connect the appliance only to aproperly grounded socket.
• The power socket must be freely accessible so that it is
possible to quickly disconnect the power cord from the
power source if necessary.
• The appliance is designed for use at home, in offices and
similar types of areas. Do not use it in very dusty or humid
rooms such as laundries or bathrooms, in areas where
chemical or explosive substances are stored, in industrial
surroundings or outdoors.
• Do not place the appliance in the vicinity of an open flame
or appliances that are sources of heat.

- 3 -
Revision 12/2021
Copyright © 2021, Fast ČR, a.s.
• Do not place the appliance on unstable surfaces such as
carpets with very long and thick fibres.
• The appliance may only be used on adry, stable, smooth
and horizontal surface.
• The appliance is equipped with travel wheels, so pay
extra attention when handling it so that it does not fall
downstairs or travel down from sloped areas. If necessary,
secure the wheels using the stoppers.
• Only use original parts to assemble the appliance. Before
starting to assemble the appliance, make sure that it is
turned off and disconnected from the power socket.
• Prior to connecting the appliance to apower socket, make
sure that the appliance is correctly assembled according
to the instructions in this user’smanual.
• Do not touch the appliance with wet or damp hands. This
applies especially when it is connected to apower socket.
• Do not expose the appliance to dripping or spraying water
or submerge it in water or another liquid.
• Do not cover or insert anything into the air inlet or air outlet
openings. Otherwise, this could damage the appliance.
• During operation there needs to be sufficient space for air
circulation of at least 30 cm on all sides of the appliance.
• Do not expose yourself to acold air current for along time.
This could have anegative effect on your health.
• To turn the appliance on or off, always use the appropriate
buttons on the control panel or the remote control. Do not
turn off the appliance by disconnecting the power cord
from the power socket.

- 4 -
Revision 12/2021
Copyright © 2021, Fast ČR, a.s.
• Always turn off the appliance and disconnect it from the
power socket when leaving it without supervision, when
not using it and before moving, disassembling, or cleaning
it.
• Do not attempt to remove the outer case of the appliance.
• Disconnect the appliance from the power socket by pulling
on the plug, never pulling on the power cord. Otherwise,
this could damage the power cord or the socket.
• If the power cord or power plug are damaged in any way,
do not use the appliance.
• Store the appliance in avertical position. It may be
transported in avertical position or tilted on the sided. If
you have already used the appliance, check that all the
condensate has been drained. After transporting it, wait at
least 1 hour before using the appliance.
• Do not use the appliance if it is not working correctly if
it has been damaged or has been submerged in water.
To avoid ahazardous situation arising, do not repair the
device yourself or modify it in any way. Have all repairs or
adjustments performed at an authorised service centre. By
tampering with the appliance, you risk voiding your legal
rights arising from unsatisfactory performance or quality
warranty.
• Installation must be performed in accordance with the
installation instructions. Incorrect installation may result in
awater leak, injury by electrical shock or fire.
• To prevent the risk of fire or injury by electrical shock, do
not use this appliance with atimer or any another similar
device that could spontaneously start this appliance.

- 5 -
Revision 12/2021
Copyright © 2021, Fast ČR, a.s.
• The appliance must be installed in accordance with
national electrical codes.
• Only use this product for the purposes that are described
in this user’smanual. Otherwise, this may result in
damage or excessive noise and vibrations.
• Use only the accessories and components that are
supplied together with the appliance and the tools
explicitly intended for its installation. The use of non-
standard parts and accessories may result in awater
leak, injury by electrical shock, fire, injury, or damage to
property.
• DO NOT ADJUST the length of the power cord of the unit
and do not use an extension cord for its power supply.
• DO NOT CONNECT the unit to apower socket to which
other electrical appliances are already connected. The
incorrect selection of an electrical power supply may result
in afire or injury by electrical shock.
• Do not cover the cable with acarpet. Do not place carpets,
fillets, or any other floor coverings on the power cord. Do
not locate the cable underneath furniture or appliances.
Lead the cable where nothing will ride over it and where
nobody can trip over it. If this occurs, immediately
disconnect the unit from the power socket.
• If the unit is tipped over during use, turn it off and immediately
disconnect it from the main power supply. Visually check that
the unit has not been damaged in any way.
• In the event of any doubts that the unit has been damaged
in any way, seek assistance from atechnician or customer
service.

- 6 -
Revision 12/2021
Copyright © 2021, Fast ČR, a.s.
• The power supply must be disconnected during
athunderstorm to prevent damage to the appliance in the
event of alightning strike.
• Disconnect the power supply to the appliance if it makes
astrange noise or if an odour or smoke is emitted.
Read this user‘smanual.
Warning:
Fire hazard.
SPECIFIC INFORMATION FOR APPLIANCES USING
REFRIGERANT GAS R290
Carefully study any warnings.
CAUTION :
For defrosting and cleaning, do not use any
other tools than those recommended by the
manufacturer.
• This appliance must be placed in an area without any
continuous source of ignition (for example an open fire, gas
or electrical appliances in operation).
• Do not puncture or do not burn it.
• Refrigerant gases may be odourless.
• This appliance must be located in rooms with an area
greater than 13 m
2
.

- 7 -
Revision 12/2021
Copyright © 2021, Fast ČR, a.s.
• This appliance contains approx. 205g of refrigerant gas
R290.
• R290 is arefrigerant gas that complies with the European
directives on the environment. Do not puncture any part of
the refrigerant circuit.
• If the appliance is installed, used and stored in anon-
ventilated area, the room must be designed to prevent the
accumulation of refrigerant leaks resulting in arisk of fire
or explosion due to ignition of the refrigerant caused by
electrical heaters, stoves, or other sources of ignition.
• The appliance must be stored in such away as to prevent
mechanical failure.
• Individuals who operate or work on the refrigerant circuit
must have the appropriate certification issued by an
accredited organisation that ensures competence in
handling refrigerants according to aspecific evaluation
recognized by associations in the industry.
• Repairs must be performed based on the
recommendations from the manufacturing company.
Maintenance and repairs that require the assistance
of other qualified personnel must be performed under
the supervision of an individual specified in the use of
flammable refrigerants.
• Check the rating label for the type of refrigerant gas used
in your appliance.
• Do not cover the ventilation slots.
• Compliance with national gas regulations shall be
observed.

- 8 -
Revision 12/2021
Copyright © 2021, Fast ČR, a.s.
• Prior to using this appliance, please read the user’smanual
thoroughly, even in cases, when one has already familiarised
themselves with previous use of similar types of appliances. Only use
the appliance in the manner described in this user’smanual. Keep
this user’smanual in asafe place where it can be easily retrieved for
future use.
• We recommend saving the original cardboard box, packaging
material, purchase receipt and responsibility statement of the vendor
or warranty card for at least the duration of the legal liability for
unsatisfactory performance or quality. In the event of transportation,
we recommend that you pack the appliance in the original box from
the manufacturer.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DESCRIPTION OF THE APPLIANCE
A1 Air outlet
A2 Control panel
A3 Handles (located along both
sides)
A4 Travel wheels
A5 Air outlet
A6 Power cord
A7 Top air inlet
A8 Top drain outlet
A9 Bottom air inlet
A10 Removable pre-filter
A11 Condensate drain hole
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DESCRIPTION OF ACCESSORIES
B1 Flexible air exhaust hose
B2 Window outlet
B3 End piece
B4 Remote control
B5 Drain hose
B6 Textile window gasket seal
(not shown)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DESCRIPTION OF THE CONTROL PANEL
C2 Cooling mode indicator
C3 Dehumidification mode
indicator
C4 Fan mode indicator
C5 Timer indicator
C6 Display
C7 Fan speed indicators (High,
Medium, Low, Auto)
W Wi-Fi indicator light
C8 On/Off POWER button
C9 FAN button for setting the fan
speed
C10 – button
C11 + button
C12 TIMER button for setting the
timer
C13 MODE button for selecting an
operating mode
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
REMOTE CONTROL
D1 Display
D2 On/Off button
D3 MODE button for selecting an
operating mode
D4 TIMER button for setting the
timer
D5 SLEEP button
D6 SWING button
D7 ▲ button
D8 ▼ button
D9 FAN button for setting the fan
speed
D10 °C/ °F button for changing
the temperature units
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
INSTALLATION
Installation location for the portable air conditioner
• Locate the portable air conditioner on an even, dry and stable surface
and within reach of agrounded power socket.
• For easier handling, the portable air conditioner is equipped with travel
wheels A4. Do not use the travel wheels A4 when you need to move
the air conditioner over carpets or similar surfaces. Avoid riding over
objects.
• To achieve optimal efficiency, maintain adistance of at least 45 cm
from the wall or other obstacles.
• To ensure sufficient efficiency of the portable air conditioner, keep all
windows and doors closed and blinds and drapes drawn.
• Make sure that there is no heat source located in the room. Do not
locate the portable air conditioner in aroom with high humidity, e.g.
laundry.
Note:
Do not use the portable air conditioner to cool aroom where
computer servers, etc. are located.
Installation, adjustment, maintenance and repairs must only be
performed by aqualified person.
Installation of flexible hose on to the portable air conditioner
• The flexible hose B1 must be connected to the portable air conditioner
and installed into awindow in accordance with the operating modes
that you wish to set. Install the flexible hose B1 when you wish to
select the operating modes: cooling, dehumidification or automatic
mode. It is not necessary to install the flexible hose B1 when you wish
to select the fan mode.
• Extend the flexible hose B1 to the required length. Put the end piece
B3 on to the end of the flexible hose B1. Insert it into the air inlet A5
and turn it to the right to secure the hose B1 in place.
• Put the window outlet B2 on to the end of the flexible hose B1.
Installing the flexible hose using the textile gasket seal
• The textile gasket seal B7 is suitable for tilt-open, sash and roof
windows. The textile gasket seal B7 is fitted with aVelcro zip tape to
make its installation in the window easier. Open the window and into
the created crevice install the textile gasket seal B7. We recommend
that you thoroughly degrease the location (frame and sash) where
you will be attaching the textile gasket seal B7 using an appropriate
cleaning agent. Remove the protective paper strip and stick the tape
on to the window frame. Never stick it on to the inner surface of the
frame, otherwise you will not be able to close the window. Then stick
on the second part of the textile gasket seal B7 on the inner or outer
part of the window sash. Check that you can close the window.
• In order to be able to insert he flexible hose B1, the gasket seal is fitted
with an integrated zip. Open the zip in such alocation that will enable
you to easily insert the flexible hose B1.
• It is not necessary to remove the textile gasket seal B7 from the
window when not using the portable air conditioner. The window can
be closed even with the gasket seal installed.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CONTROLS OF THE PORTABLE AIR CONDITIONER
A. CONTROL PANEL
• Insert the power plug into apower socket. Now the portable air
conditioner sets itself to the stand-by mode.
Turning the portable air conditioner on and off
• To turn on the portable air conditioner, press button POWER C8. Press
it again to turn the portable air conditioner off.
Note:
Never turn off the portable air conditioner by pulling the power
cord out of the power socket. Turn off the portable air conditioner
using button POWER C8, wait afew minutes and then pull out
the power cord.
EN
Portable Air Conditioner Wi-Fi
User'smanual

- 9 -
Revision 12/2021
Copyright © 2021, Fast ČR, a.s.
OPERATING MODES
1. Cooling mode
• Repeatedly press button MODE C13 until the cooling indicator C2 is lit.
Use buttons –/+ C10 aC11 to set the desired temperature. You can set
the temperature in the range from 18 to 32 °C.
• Using button FAN C9, set the fan speed. Repeatedly press button FAN
C9 to switch the speed in the following order: High (high speed) –
Medium (medium speed) – Low (low speed) – Auto (automatic speed).
Each time the button is pressed, the respective indicator will be lit on
the control panel.
2. Fan mode
• Repeatedly press button MODE C13 until the fan mode indicator C4 is
lit. Using button FAN C9, set the fan speed. Repeatedly press button
FAN C9 to switch the speed in the following order: High (high speed)
– Medium (medium speed) – Low (low speed). Each time the button
is pressed, the respective indicator will be lit on the control panel
and, likewise, agraphical indicator will show the selected speed on
the display C6. In this mode, it is not possible to set the temperature,
nor is it necessary to connect the flexible hose B1 to the portable air
conditioner.
3. Dehumidification mode
• Make sure that the flexible hose B1 is connected to the air conditioner
and goes into the window. Repeatedly press button MODE C13 until
the dehumidification indicator C3 is lit. The display C6 will show
.
It is not possible to set the temperature or fan speed in this mode. The
fan speed is automatically set.
4. Automatic mode
• If you select an automatic mode, the portable air conditioner will
automatically select an operating mode based on the temperature in
the room.
• Repeatedly press button MODE D3 until the arrow on the display D1
stops at the symbol
.
• Use button FAN D9 to set the fan speed. Repeatedly press button
FAN D9 to switch the speed in the following order: High (high speed)
– Medium (medium speed) – Low (low speed) – Auto (automatic
speed). Each time the button is pressed, the arrow at the speed bar on
the display D1 will switch.
• The portable air conditioner will start in the fan mode, when the
temperature in the room is less than 23 °C, and in the cooling mode
when the temperature in the room is higher than 23 °C.
Functions of the portable air conditioner
1. Automatic start function
• Start the portable air conditioner by pressing button POWER C8.
Using button MODE C13, select the operating mode in which you wish
to turn on the portable air conditioner. Use buttons –/+ C10 and C11
to set the desired temperature and use button FAN C9 to select afan
speed as required. Turn off the portable air conditioner using button
POWER C8.
• Now press button TIMER C12, awristwatch icon together with
aflashing time will appear on the display C6. Use the buttons –/+
C10 andC11 to set the time after which the portable air conditioner will
turn on automatically. The automatic start time can be set in the range
between 30 minutes and 24 hours (set in 30 minute intervals until 10
hours, and one hour intervals until 24 hours).
• After afew seconds, the time is saved to the memory of the air
conditioner and the automatic start indicator appears on the display
C6. Once the set time elapses, the portable air conditioner will start
automatically.
• If button TIMER C12 or POWER C8 are pressed after the automatic
start is set, then this setting will automatically be cancelled.
2. Automatic shut-off function
• When the portable air conditioner is running, press button TIMER
C12, awristwatch icon together with aflashing time will appear on
the display C6. Use the buttons –/+ C10 andC11 to set the time after
which the portable air conditioner will automatically stop.
• The automatic shut-off time can be set in the range between 30
minutes and 24 hours.
• After afew seconds, the time is saved to the memory of the air
conditioner and the automatic shut-off indicator appears on the
display C6. Once the set time elapses, the portable air conditioner will
shut off automatically.
• If button TIMER C12 or POWER C8 are pressed after the automatic
shut-off is set, then this setting will automatically be cancelled.
3. Wi-Fi function (valid only for Wi-Fi models)
• You can also control the mobile air conditioner directly from your
smart phone thanks to the “Sencor HOME” application.
• Install the “Sencor HOME” application on to your smart phone.
The application is available for operating systems iOS (App Store)
and Android (Google Play). Further follow the instructions in the
application.
• In order to control the mobile air conditioner using the installed
application, it is necessary the Wi-Fi is turned on.
• While the mobile air conditioner is off (it is in stand-by mode), press
the
button C9 six times within four seconds to reset the Wi-Fi
signal. An audible alert sounds. If the function is on, the indicator C2
will be lit.
• For simpler installation of the control panel of the air conditioner, you
can use the following QR code!
B. REMOTE CONTROL
Inserting and replacing batteries
• Slide out the battery compartment cover, which is located on the rear
side of the remote control. Place two AAA/LR03 (2× 1.5 V) alkaline
batteries into the battery compartment and close the cover.
• When inserting the batteries ensure the correct polarity as shown in
the battery compartment.
• When replacing the batteries, always use batteries of the same type,
never combine old and new batteries or batteries of various types.
Note:
Removing the batteries from the remote control will delete all
the settings. After new batteries are inserted the default remote
control settings as programmed by the manufacturer will be
renewed.
• If you will not be using the remote control for longer than 2 months,
remove the batteries.
Using the remote control
• For the remote control to work correctly, ensure that the maximum
distance of the remote control from the portable air conditioner is
not greater than 7 m and that there is no obstacle between the
remote control and the portable air conditioner that could prevent the
transmission of the signal.
• Point the remote control directly at the portable air conditioner. The
transmission of the signal is confirmed by ashort sound signal.
• Do not expose the remote control to direct sunlight or high
temperatures. Otherwise the signal may not be transmitted.
Turning the portable air conditioner on and off
• To turn on the portable air conditioner, press button D2 once. Press
button D2 again to turn the portable air conditioner off.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OPERATING MODES
1. Cooling mode
• Repeatedly press button MODE D3 until the arrow on the display D1
stops at symbol
. Use buttons ▲/▼ D7 and D8 to set the desired

- 10 -
Revision 12/2021
Copyright © 2021, Fast ČR, a.s.
temperature. You can set the temperature in the range from 18 to
32 °C.
• Use button FAN D9 to set the fan speed. Repeatedly press button
FAN D9 to switch the speed in the following order: High (high speed) –
Medium (medium speed) – Low (low speed) – Auto (automatic speed).
Each time the button is pressed, the arrow at the speed bar on the
display D1 will switch.
2. Fan mode
• Repeatedly press button MODE D3 until the arrow on the display D1
stops at symbol
.
• Use button FAN D9 to set the fan speed. Repeatedly press button
FAN D9 to switch the speed in the following order: High (high speed)
– Medium (medium speed) – Low (low speed). Each time the button is
pressed, the arrow at the speed bar on the display D1 will switch.
Note:
In the fan mode, it is not possible to set the temperature,
therefore no temperature information will be shown on the
display D1.
3. Dehumidification mode
• Repeatedly press button MODE D3 until the arrow on the display D1
stops at symbol
. “dH” is shown on the display D1.
• It is not possible to change the fan speed in the dehumidification
mode.
4. Automatic mode
• If you select an automatic mode, the portable air conditioner will
automatically select an operating mode based on the temperature in
the room.
• Repeatedly press button MODE D3 until the arrow on the display D1
stops at symbol
.
• Use button FAN D9 to set the fan speed. Repeatedly press button
FAN D9 to switch the speed in the following order: High (high speed) –
Medium (medium speed) – Low (low speed) – Auto (automatic speed).
Each time the button is pressed, the arrow at the speed bar on the
display D1 will switch.
• The portable air conditioner will start in the fan mode, when the
temperature in the room is less than 23 °C, and in the cooling mode
when the temperature in the room is higher than 23 °C.
Functions of the portable air conditioner
1. Sleep function
• The sleep function is used to reduce overnight power consumption,
when aconstant temperature is not necessary.
• Selecting an operating mode – cooling – see previous part of the
user’smanual.
• Press button D5, symbol
will appear on the display D1. The
portable air conditioner will run in the last selected mode.
• For the cooling mode, within two hours, the temperature will increase
by 2 °C. This new temperature will be maintained for aperiod of 6
hours and then the portable air conditioner will turn itself off.
• The sleep function can be cancelled at any time by pressing button
D5, D3 or D9.
• The sleep function cannot be set in the fan and dehumidification
modes.
2. Automatic start and shut-off function
Automatic start
• The automatic start function makes it possible to set atime after which
the portable air conditioner will start automatically.
• Start the portable air conditioner by pressing button D1. Using button
D3, select the operating mode in which you wish to turn on the
portable air conditioner. Use buttons ▲/▼ D7 and D8 to set the
desired temperature and use button D9 to select afan speed as
required. Turn off the portable air conditioner using button D1.
• Press button D4 twice, the time and symbol
will appear on
the display D1. Use buttons ▲/▼ D7 andD8 to set atime after which
the portable air conditioner will automatically start. The automatic
start time can be set in the range between 30 minutes and 24 hours
(set in 30 minute intervals until 10 hours, and one hour intervals until
24 hours).
• Press button D4 once to confirm the setting. The set time will appear
on the display D1 and symbol
will remain lit.
• Once the set time elapses, the portable air conditioner will start
automatically. If button D4 or D2 are pressed after the automatic start
is set, then this setting will automatically be cancelled.
Automatic shut-off
• The automatic shut-off function makes it possible to set atime after
which the portable air conditioner will shut off automatically.
• While the portable air conditioner is turned on, press button D4 once.
The time and symbol
will be shown on the display D1.
• Use buttons ▲/▼ D7 andD8 to set atime after which the portable
air conditioner will automatically turn off. The automatic shut-off time
can be set in the range between 30minutes and 24 hours (set in 30
minute intervals until 10 hours, and one hour intervals until 24 hours).
• Press button D4 once to confirm the setting. The set time will appear
on the display D1 and symbol
will remain lit.
• Once the set time elapses, the portable air conditioner will shut off
automatically. If button D4 or D2 are pressed after the automatic shut-
off is set, then this setting will automatically be cancelled.
3. Flap angle function
• Button D7 can be used to select either left or right air flow. Press
button D7 once, an arrow and symbol
will appear on the display
D1. Pressing button D7 will cause the arrow to disappear and the
function to be cancelled.
Changing temperature units
• While the air conditioner is in stand-by mode, press button D10 to
toggle the temperature units from °Cto °F and vice versa.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
MAINTENANCE AND CLEANING
• Before cleaning the portable air conditioner, turn it off and wait afew
minutes, and then pull the power cord out of the power socket.
Cleaning the air filters
• If the portable air conditioner is used regularly, it is necessary to
clean the air filters at least once every 14 days to avoid the fan
from becoming clogged with dust. Based on the model of your air
conditioning unit, clean the following filters:
– Clean both the air filter located behind the removable protective
grille of the top air inlet A7, as well as the air filter located behind
the removable grille of the bottom air inlet A9.
• Carefully remove the protective grille and take out the respective
filters. To remove the dust, use avacuum cleaner. In the event of
greater soiling, wash the filter by hand in asolution of lukewarm water
(max. 40 °C) and neutral detergent. Then thoroughly rinse it under
running water and allow it to dry naturally. Do not dry it in aclothes
dryer or in direct sunlight. Once the filter is dry, you can install it back
in its place.
Note:
Do not use aportable air conditioner without the air filters
properly installed and do not use it with wet or damp air filters.
• The water collection (condensation) tank must be drained immediately
when the code “Ft” appears on the display C1 and also before this
appliance is stored in order to prevent the formation of moulds.
• In households with pets, it is necessary to wipe the grille regularly to
prevent it from becoming clogged by animal fur.
Cleaning the outer case
• To clean the outer case, use asoft wiping cloth dipped in asolution of
lukewarm water and neutral detergent. Then wipe the surface dry.
• When cleaning it, do not spray the portable air conditioner with water
or any other liquid, do not pour water on it or submerge it in water or in
any other liquid.
• Do not use abrasive cleaning products, solvents, petrol, etc. for
cleaning.

- 11 -
Revision 12/2021
Copyright © 2021, Fast ČR, a.s.
Storing the portable air conditioner
• In order to dry it and to prevent the formation of moulds, leave the
portable air conditioner running in awarm room in the fan mode for
approximately 12 hours.
• Disconnect the flexible hose B1 and store it in asafe place out of the
reach of children.
• Drain all the condensate from the condensate tank – see chapter
“Condensate drain outlet”.
• Clean the air filters and reinstall them. Wipe the outer case of the
portable air conditioner. Remove the batteries from the remote control.
• Store the air conditioner in acool, dry and dark location.
Condensate drain outlet
• If the water level inside the condensate tank reaches apredetermined
level, the portable air conditioner will show “Ft” (full condensate
tank) on the display C6. In order to drain the condensate from the air
conditioner, proceed as follows:
1. Disconnect the power plug from the power socket.
2. Carefully re-locate the portable air conditioner to alocation where
the water may be drained.
3. Underneath the drain outlet A11, place acontainer into which the
condensate will flow. Carefully remove the plug of the drain outlet
A11. Connect the drain hose B6 and allow the condensate to flow
out.
4. Once the condensate tank is empty (condensate has stopped
flowing), disconnect the drain hose B6 and put the plug back into the
drain outlet A11.
5. Insert the power plug into apower socket and turn on the portable air
conditioner.
• If you need to ensure the condensate to be continuously drained from
the portable air conditioner, it is possible to connect the drain hose B6
to awaste water drain. Proceed as follows:
1. Disconnect the power plug from the power socket.
2. Remove the plug of the top drain outlet A8. Connect the drain
hose B6. If the length of the drain hose B6 is insufficient, then it is
necessary to purchase alonger hose of the same type. Never extend
the length of the drain hose B6 using extensions.
3. Connect the end of the drain hose B6 to the waste water drain.
4. Insert the power plug into apower socket and turn on the portable air
conditioner.
Note:
The drain hose B6 should be installed at the same height or
lower than the top drain outlet A8. Otherwise, the condensate
will not be properly drained from the condensate tank.
Putting into operation again
• Check that the power cord and plug are not damaged and that the
air filters are clean. Insert anew set of batteries into the remote
control. Proceed according to the instructions in section “Inserting and
replacing batteries”. Install the portable air conditioner according to
the instructions contained in the preceding part of this user’smanual
“Installation”.
TROUBLESHOOTING
Error messages
Shown on
the display
Meaning Solution
Low
temperature
The portable air conditioner has
asystem that prevents freezing at very
low temperatures.
The air conditioner will start again once
the internal system is defrosted.
Defect of the
heat sensor
Contact an authorised service centre.
Full
condensate
tank
Empty the condensate tank. Proceed
according to the instructions in section
"Condensate drain outlet" described
previously in this user'smanual.
Note:
In the event that one of the aforementioned faults occurs,
turn off the portable air conditioner and check for the cause of
the fault. Turn it on again, and if the fault reoccurs, turn it off,
disconnect the power cord from the power socket and contact
the manufacturer, an authorised service centre or aperson with
relevant qualifications and have the unit repaired.
Troubleshooting
• Before contacting an authorised service centre, please check the
appliance according to the following instructions:
Problem Possible cause Remedy
The portable air
conditioner did
not turn on.
There is no current in
the power socket.
Engage the
circuit breaker or,
alternatively, try
adifferent power
socket.
The power plug is not
inserted in apower
socket.
Connect the power
plug to the power
socket.
The internal safety fuse
is disengaged.
Wait 30 minutes, and
if the problem persists,
please contact an
authorised service
centre.
The portable air
conditioner runs
only for ashort
time.
The flexible air
exhaust hose B1 is
not connected or it is
blocked.
Turn off the air
conditioner, disconnect
the hose, check that
it is not blocked and
reconnect the hose.
Air inlets A7 and A9 are
blocked.
Remove the obstacles
preventing air supply to
the inlets.
The portable air
conditioner is on,
but is not cooling.
The windows and doors
of the room are open.
Make sure that all
doors and windows are
closed.
There are heat sources
inside the room.
If possible remove
these heat sources.
The flexible air
exhaust hose B1 is not
connected.
Attach the flexible
hose B1.
The room area is too
large.
Perform adouble-
check of the cooled
area.
An unpleasant
odour is sensed
while it is running.
The air filters are
clogged with dirt and
dust or animal fur.
Turn off the air
conditioner and clean
the filters according
to the provided
instructions.
The portable
air conditioner
turns off approx.
3minutes after
it is turned on
again.
Then
compressor'ssafety
fuse is protecting the
air conditioner against
damage if turned on
sooner than after 3
minutes.
Wait several minutes
and then turn the air
conditioner on again.
An error message
appeared on the
display C1.
Proceed according
to the instructions
in section "Error
messages".

- 12 -
Revision 12/2021
Copyright © 2021, Fast ČR, a.s.
TECHNICAL SPECIFICATIONS
SAC MT9030C / SAC MT9031C
Power supply ........................................................................220–240 V~ / 50 Hz
Cooling power ................................................................................ 9,000 Btu / hour
Power input / Cooling power .................................................. 1,200 W/ 1,000 W
El. current draw / Cooling draw .....................................................5.21 A/ 4.35 A
EER cooling factor......................................................................................................2.6
Dehumidification capacity ........................................................................ 28 l / hour
Capacity of the built-in condensate tank .........................................................0.5 l
Refrigerant type and weight ...........................................R290 / 205 g / GWP 3
Air flow volume .............................................................................................290 m
3
/h
Noise level ............................................................................65 dB (A) (high setting)
Maximum permitted value of excess operating pressure:
Suction / exhaust part of the cooling circuit ....................................1.2/2.3 MPa
Dimensions of the portable air conditioner (w× d × h) ......440 × 325 × 695 mm
Weight ............................................................................................................29 kg (net)
Operating temperature (cooling) ...............................................................18–32 °C
Recommended room area (Central Europe) ........................................31/ 35 m
2
Recommended room size (Central Europe) ........................................80-91 m
3*
*applies for the calculated climatic conditions value typical for Central
Europe. For standard rooms with ceilings at standardised heights. The
provided values may differ when the appliance is used in sectioned
areas, in areas with multiple heat sources, heavily glazed or/and poorly
insulated areas.
If you know that you are purchasing the air conditioner for an area with
the above-described characteristics, select amodel with ahigher power
output for the given area.
The declared noise emission level of the appliance is 65 dB(A), which
represents alevel Aof sound power with respect to areference sound
power of 1 pW.
Note:
The efficiency of the portable air conditioner may be reduced in
the event that it is used outside the above described operating
temperature range.
We reserve the right to change text and technical specifications.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
INSTRUCTIONS AND INFORMATION REGARDING THE DISPOSAL OF
USED PACKAGING MATERIALS
Dispose of used packaging material at asite designated for waste in your
municipality.
DISPOSAL OF USED ELECTRICAL AND ELECTRONIC EQUIPMENT
This symbol on products or original documents means that
used electric or electronic products must not be added to
ordinary municipal waste. For proper disposal, renewal and
recycling, hand over these appliances to determined
collection points. Alternatively, in some European Union
states or other European countries you may return your
appliances to the local retailer when buying an equivalent
new appliance. Correct disposal of this product helps save
valuable natural resources and prevents potential negative effects on the
environment and human health, which could result from improper waste
disposal. Ask your local authorities or collection facility for more details. In
accordance with national regulations penalties may be imposed for the
incorrect disposal of this type of waste.
For business entities in European Union states
If you want to dispose of electric or electronic equipment, ask your retailer
or supplier for the necessary information.
Disposal in other countries outside the European Union.
This symbol is valid in the European Union. If you wish to dispose of this
product, request the necessary information about the correct disposal
method from the local council or from your retailer.
This product meets all the basic requirements of EU
directives related to it.

FAST ČR, a.s.
U Sanitasu 1621
CZ-251 01 Říčany
www.sencor.eu