7
7. BLOWER REMOVAL (HORIZONTAL DISCHARGE ONLY)
These range hoods are factory shipped with the blower mounted for a vertical discharge configuration. For a horizontal discharge
configuration, disassemble the blower from the inner top of the hood (see procedure below). It will be assembled to the inner back of the
hood once the hood is mounted on the wall.
2) Using a 5/16” socket, or a Robertson or a Phillips no. 2 screwdriver,
remove the 4 blower mounting screws (2 on each side) from the inner
top of the hood. Set the blower and screws aside.
1) Unplug the blower.
HD0386
RIGHT SIDE MOUNTING
SCREW LOCATIONS
HD0385
LEFT SIDE MOUNTING
SCREW LOCATIONS
HE0123
8. INSTALL THE ADAPTER/DAMPER
HORIZONTAL DISCHARGE
Mount the 3¼” x 10” adapter/damper to the back of the hood using
2 no. 8 x 3/8” screws (included). Seal the adapter/damper to the hood using
metal foil duct tape.
NOTE: The wall ducting must be properly prepared to receive the adapter.
Before performing the installation, make sure the adapter fits easily
in the duct.
HJ0062
SCREW LOCATIONS
VERTICAL DISCHARGE
Mount the 3¼” x 10” adapter/damper to the top of the hood using 2 no. 8 x 3/8” screws
(included). Seal the adapter/damper to the hood using metal foil duct tape.
HJ0065
SCREW LOCATIONS