Loading ...
Loading ...
Loading ...
Performance Data Sheet
Model: GE RPWF
Use Replacement Cartridge RPWR
The concentration of the indicated substances in water entering the system was reduced to a concentration lessthan or equal tothe permissible
limit for water leaving the system as specified in NSF/ANStStandard 42 and Standard 53. System tested and certified by NSFInternational against
NSF/ANSIStandard 42 and Standard 53 for the reduction of substances listed below.
Capacity 170 Gallons 643.5 Liters). Contaminant Reduction Determined b' NSF testing.
Substance Tested NSF specified Avg% Water
for Reduction Average Influent Challenge Concentration Reduction Concentration
2.0 mg/L _+10%
97.4%
2.0 mg/L
7,633,333 pts/mL
109 MFL
0.009 mg!L
0.016 mg!L
0.08 mg/L
104,750 cysts/L
0.140 mg/L
0.158 mg/L
0.006 mg/L
0.006 mg!L
0.002 mg/L
0.222 mg/L
0.015 mg!L
0.218 mg!L
0.278 mg/L
*Based on the useof Cryptosporidium parvum oocysts.
At least 10,000 particles/mL
107 to 108 fibers/L; fibers
greater than lOpm in length
0.009 mg/L _+10%
0.015 mg/L _+10%
0.08 mg!L _+10%
Minimum 50,000 cysts/L
0.15 mg!L _+10%
0.15 mg/L _+10%
0.006 mg/L _+10%
0.006 mg/L _+10%
0.002 mg/L _+10%
0.225 mg/L _+10%
0.015 mg/L _+10%
0.210 mq/L_+lO%
0.300 mg/L _+10%
99.0%
99.99%
94.4%
96.4%
98.8%
99.99%
99.3%
98.3%
91%
88.3%%
99%
99.8%
93.5%
99.9%
97.7%
0.05 mg/L
71,850 pts/ml
<1 MFL
0.0005 mg/L
0.001 mg/L
0.001 mg/L
3 cyst!L
0.001 mg/L
0.002 mg/L
0.0003 mg/L
0.0007 mg/L
0.00002 mg/L
0.0005 mg/L
0.001 mg/L
0.0001 mg/L/L
0.0015 mg/L
Max Permissible
Product Water
Concentration
N/A
N/A
N/A
0.003 mg!L
0.005 mg!L
0.04 mg/L
N/A
0.010 mg!L
0.010 mg/L
0.002 mg/L
0.002 mg/L
0.0002 mg/L
0.075 mg!L
0.003 mg/L
0.07 mcz!L
N/A
Requirements
>50%
>85%
->99%
N/A
N/A
N/A
->99.95%
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
->95%
The following pharmaceutical reduction claims have not been certified by NSF International. Claims tested and verified
by independent laboratory:
' I
Contaminant
Reduction
Average Influent
1088 ng/L
845 ng!l
898 ng/L
945 ng/L
403 ng!L
NSFspecified
ChallengeConcentration
N/A
N/A
N/A
N/A
N/A
Avg%
Reduction
99.5%
99.4%
98.8%
99.4%
99.5%
Test Report
J-00102044
J-00106249
J-00102069
J-00102058
J-00102065
J-00102059
J-00102057
J-00102052
J-00102053
J-00102054
J-00104087
J-00102063
J-00102067
J-00102061
J-00102064
J-00102070
, Mox Permissible
Average Product Woter i _ ProductWoter NSF
...... Concentration ' Concentration Test Repo_
5.0 ng/L N/A J-00103221
5.0 ng/L N/A J-00103221
9.9 ng/L N/A J-00103726
5.5 ng/L N/A J-00103727
2.0 ng/L N/A J-00103221
Application Guidelines/Water Supply Parameters
Service Flow Water Pressure
Water Su_ Water Temperature
It is essentialthat the manufacturer'srecommendedinstallation, maintenanceand filter replacementrequirementsbecarriedout for the product to performas advertised.
Seeinstallation Manualfor Warranty information.
Note: While the testing was performed under standard laboratory conditions,
actual performance may vary.
Replacement Cartridge: RPWEForestimated costs of replacement elements
please call 1-800-626-2002 or visit our website at www.geapplianceparts.com.
Z_WARNING
Toreduce the risk associated with ingestion of contaminants:
, Do not use with water that is microbiologically unsafe or of unknown quality
without adequate disinfection before and after the system. Systems certified
for cyst reduction may be used on disinfected water that may contain filterable
cysts. EPAEstablishment Number 070595-MEX-O01.
NOTICE
Toreduce the risk associated with property damage due to water leakage:
, Read and follow use instructions before installation and use of this system.
, Installation and use MUSTcomply with all state and local plumbing codes.
, Do not install if water pressure exceeds 120 psi (827kPa).If your water pressure
exceeds 80 psi,you must install a pressure-limiting valve.Contact a plumbing
professional if you are uncertain how to check your water pressure.
, Do not install where water hammer conditions may occur. If water hammer
conditions exist you must install a water hammer arrester. Contact a plumbing
professional if you are uncertain how to checkfor this condition.
, Do not install on hot water supply lines The maximum operating water
temperature of this filter system is 100° F(38° C).
, Protect filter from freezing. Drain filter when temperatures drop
below 33°F(0.6°C).
, The disposable filter cartridge must be replaced every 6 months at the
rated capacity, or sooner if a noticeable reduction in flow rate occurs.
For conditions of use, health claims certified by the California Department of Public
Health, and replacements, see performance data sheet. California Department
of Public Health Certification #11-2110. The contaminants or other substances
removed or reduced by this water filter are not necessarily in all users' water.
GE
Appliances
Appliance Park
Louisville, KY 40225
geapplianceparts.com
44
_I Systemtestedand certifiedby NSF
InternationalagainstNSF/ANSIStandard
42andStandard53in modelGERPWF
forthe reductionofthe claimsspecified
ontheperformancedatasheet,
34-8708-7119-0
EPA #070595-MEX-001
© 2012 General Electric Company PC71879
Loading ...
Loading ...
Loading ...