Kenmore 229960121 gas-fired hot water boiler

User Manual - Page 8

For 229960121.

PDF File Manual, 24 pages, Download pdf file

Loading ...
Loading ...
Loading ...
7.Any_mproperoperationofthecommonventingsystem
shouldbecorrectedsotheinstallationconformswiththe
NationalFuelGasCode,ANSIZ2231-latestrevisionWhen
resizinganyportionofthecommonventingsystem,the
commonventingsystemshouldberesizedto approach
theminimumsizeasdeterminedusingtheappropriate
tablesin Part11 in theNationalFuelGasCode,ANSI
Z223.1-latestrevision.
For boilers for connection to gas vents or chimneys,
vent installations shall be in accordance with Part 7,
Venting of Equipment, of the National Fuel Gas Code,
ANSI Z223.1-1atest revision and applicable provisions
of the local building codes.
Vent connectors serving appliances vented by natural
draft shall not be connected into any portion of
mechanical draft systems operating under positive
pressure,
ROOF
RIDGE
3/4 HT MAXIMUM
HT
MUSTSLOPEUP
AT LEAST 1/41NCH
PER FOOT OF
HORIZONTAL RUN
HORIZONTAL INSTALLATION
TO FURNACE VENT TO CHIMNEY
OR BOILER DAMPER INSTALL VENT DAMPER WITH
ACTUATOR TO SIDES OF
VENT ONLY. DO NOT MOUNT
ABOVE OR BELOW VENT.
VERTICAL INSTALLATION
TO CHIMNEY
'6 ©
FLOW VENT
DAMPER
ACTUATOR MAY BE
TO FURNACE N INSTALLED IN ANY POSITION
OR BOILER
U
CAUTION: DO NOT INSTALL
THE VENT DAMPER
WmHIN 6 in. (152 ram) OF
COMBUSTIBLE MATERIAL
3HIMNEY
BOILER WATER HEATER
TYPICAL INSTALLATION FOR VENT DAMPER
NOTE CAUTION AND Foo'rNOTES
1. Installthe vent damper to ser,Ace only the single appliance for
which it is intended,if improperlyinstalled, a hazardous condition,
such as an explosion or carbon monoxide poisoning,could result.
2. Do not install _e vent damper on vent pipe curve.
3, Do not run wires near high temperature surfaces. Use stand-off
brackets if necessary
7o0o_