2
After regulation repeat the operations indicated in paragraph “2. PRESSURE
REGULATOR” at page 15 and 20.
If the range has been disconnected and then connected again to the gas supply line
repeat the operations indicated in paragraph “5. LEAK TESTING” at page 20.
IMPORTANT:
After conversion to LP/PROPANE gas has been carried out a󰀩x near the data plate
the conversion label supplied and also a󰀩x a conversion label at page 3 of this
instruction manual.
After conversion back to the original gas (NATURAL GAS) has been carried
out remove, near the data plate and at page 3 of this instruction manual, the
LP/PROPANE conversion labels. Save the labels removed for future use.
A
U
T
O
Fig. 2.7
R
1
R
3
R
2
R
1
Regulation screw (Triple-ring and semirapid burner)
R
2
Regulation screw (Inner crown of dual burner)
R
3
Regulation screw (Outer crown of dual burner)
SETTING THE BURNER MINIMUM
When switching from one type of gas to another, the minimum ow rate must also be correct: the ame should not go out even when
passing suddenly from maximum to minimum ame.
To regulate the ame (g. 2.7) follow the instructions below:
Triple-ring and semirapid burner
Light the burner.
Set the gas valve to position (minimum rate).
Remove the knob.
With a thin screwdriver, turn the regulation screw “R
1
” until adjustment is correct.
Inside crown of DUAL burner
Light the DUAL burner.
Set the gas valve to position (minimum rate of inner crown).
Remove the knob
With a thin screwdriver, turn the regulation screw “R
2
” until adjustment is correct.
Outside crown of DUAL burner
Light the DUAL burner.
Set the gas valve to position (minimum rate of outer crown and maximum rate of inner crown).
Remove the knob.
With a thin screwdriver, turn the regulation screw “R
3
” until adjustment is correct.
For LP/PROPANE gas, tighten the adjustment screws completely.