All gas connections must be made according to national and local codes. This gas
supply (service) line must be the same size or greater than the inlet line of the
appliance. Sealant on all pipe joints must be resistant to te action of LP/Propane gas.
The range is equipped for the use with NATURAL gas. It is design-certified by CSA
International for NATURAL and L.P. gases with appropriate conversion.
The model/serial rating plate, located on the inner side of the storage compartment
pivoting panel, has information on the type of gas that can be used. If this information
does not agree with the type of gas available, check with the local gas supplier. See
page from 21 to 23 for L.P. gas conversion inctructions.
1. Manual Shut-off Valve (fig. 2.1):
A manual shut-off valve must be installed in an accessible location in the gas line
external to the appliance for the purpose of turning on or shutting off gas to the
appliance (In Massachusetts such shutoff devices should be approved by the Board
of State Examiners of Plumbers & Gas Fitters). This valve should be located in the
same room as the range and should be in a location that allows ease of opening and
closing (in a position where it can be reached quickly in the event of an emergency).
Do not block access to the shutoff valve. The valve is for turning on or shutting off
gas to the appliance.
2. Pressure Regulator:
a) All heavy duty, commercial type cooking equipment must have a pressure regulator
on the incoming service line for safe and efficient operation, since service pressure
may fluctuate with local demand.
Before installing the regulator mount the 1/2” NPT (conical) male connector to the
regulator (see picture 2.2a). Gasket supplied has to be placed between 1/2” NPT
(conical) connector/extension pipe male pipe fitting (see picture 2.2c).
The regulator supplied with this range must be installed before any gas connections
are made.
Use supplied pressure regulator only.
b) Assemble the extension pipe + pressure regulator group to the range manifold
interposing the gasket supplied.
Fig. 2.1
Explosion Hazard
Use a new CSA or UL approved
gas supply line.
Install a shut-off valve.
Securely tighten all gas
connections.
If connected to LP, have a
qualified person make sure gas
pressure does not exceed 14”
water column.
Examples of a qualified
person include licensed
heating personnel, authorized
gas company personnel, and
authorized service personnel.
Failure to do so can result in
death, explosion, or fire.