To Use Timer (Auto Start/Stop) Feature:
When the unit is on or off, press the Timer button and the “Timer On” indicator light
illuminates. It indicates that the Auto Start/Stop program is initiated.
To switch to off press the Timer button again and the “Timer Off” indicator light
illuminates. It indicates that the Auto Stop program is initiated.
Press or hold the Up or Down button to change the Auto Time by ½ hour
increments up to 10 hours or 1 hour increments up to 24 hours. The control will count
down the time remaining until start.
The selected time will display for five (5) seconds and then will automatically revert back to
display the previous temperature setting or room temperature when the unit is on. (Note-
when the unit is off there is no display.)
Turning the unit ON or OFF at any time or adjusting the timer setting to 0.0 will cancel the
Auto Start/Stop program.
To Check Filter Feature:
This feature is a reminder to clean the Air Filter for more efficient operation. The LED light will
illuminate after 250 hours of operation. To reset after cleaning the filter, simply press the
Check Filter button and the light will go off.
Digital Display:
Displays the set temperature in “C” or “F” and the Auto-Timer settings. While on Fan Only
Mode it shows the room temperature.
Error Codes
AS- Room temperature sensor error
- Unplug the unit and plug back in.
- If error repeats call for service.
- In Fan only mode it will display “LO” or “HI”.
- Evaporator temperature sensor error
- Unplug the unit and plug it back in.
- If error repeats, call for service.