XTi2 Series Power Amplifiers
page 6
Operation Manual
Low Pass Mode
Factory Preset #4: BRG SUBS
Putting the amplifier in BRG SUBS
(bridged subs) mode allows you to
bridge the amplifier for use with a single
8 or 4 ohm subwoofer. The inputs are
automatically summed, a 90Hz 4th order
(24dB/octave) LowPass filter is enabled,
and the output mode is put into bridge-
mono mode. The XTi2 Series amplifiers
come pre-loaded with a preset that makes
it easy to configure the amplifier for this
operation.
Before you get started ensure that you:
1. Connect signal source to Channel 1 and Channel 2 using XLR connectors (the amplifier inputs will
automatically be summed together when selecting this preset).
2. Connector the speaker as shown.
a. If using the binding post outputs, connect the positive terminal of the speaker to the positive
terminal of Channel 1 and the negative terminal of the speaker to the positive terminal of Channel
2.
b. If using a Speakon
®
connector, connect the positive terminal of the speaker to 1+ and the
negative terminal to 2+. Plug the connector into the Channel 1 output only.
Follow these quick steps to configure the amplifier for XOVER operation:
1. Push the “Set/Enter” button and you will see the word “Preset” flashing.
2. Push the “Set/Enter” button again to enter the list of presets in the amplifier.
3. Push the “Next/Down” or “PREV/UP” button until the screen displays “XOVER”.
4. Push the “Set/Enter” button to confirm your selection.
5. The display will now read “XOVER” with the Y icon and XOV icon highlighted.