A
C
A- Plug with compression nut
C- Pex tubing
4. The ice maker is equipped with a built-in water strainer.
If your water conditions require a second water strainer,
install it in the 1/4” (0.63 cm) water line at either tube
connection. Obtain a water strainer from your nearest
appliance dealer.
5. Plug in refrigerator or reconnect power.
Move the Refrigerator Drawers
to Final Location
1. Place top of cardboard carton or plywood under the
appliance. Remove dolly.
2. Do not remove film or cover.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
2. Turn ON shutoff valve.
3. Check for leaks. Tighten any
connections (including
connections at the valve) or
nuts that leak.
3. Plug into a grounded 3 prong outlet.
Excessive Weight Hazard
Use two or more people to move and install or uninstall
appliance.
Failure to do so can result in back or other injury.
4. Move the refrigerator drawers straight back and evenly in
front of the opening.
Level the Refrigerator Drawers
IMPORTANT:
Overlay Model-Be sure to install the custom overlay drawer
panels before leveling the refrigerator drawers. See “Install
Custom Overlay Drawer Panels.”
Before installing the refrigerator drawers, be sure that the
countertop is level.
If the countertop is not level, adjust the refrigerator drawers’
leveling legs until the appliance is square with the
countertop. Be sure to maintain 3/8” (0.95 cm) minimum gap
between the top of the drawer and the countertop.
1. Open the top drawer and place the level across the top
drawer, as shown.
Check the level
from left to right.
A
A- Check the level
from left to right.
2. Turn the leveling legs (front and
back) until the top drawer
measures level from left to right.
3. Remove the level and close the top drawer. Check the gap
between the top of the drawer and the countertop. If the
gap measures less than 3/8” (0.95 cm) minimum, turn all
four leveling bolts equally to the left to raise the leveling
legs (this will lower the appliance). Recheck the level.
4. Open both drawers less than midway. Place the level on
the side flange beside the drawers as shown.
Turn the front leveling bolts together in order
to either raise or lower
the appliance until the
sides of the refrigerator
drawers are plumb.
A
A- Check the level
from front to back.
5. Remove the level and close the drawers. Recheck the gap
between the top of the drawer and the countertop.
If the gap measures less than 3/8” (0.95 cm), turn all four
leveling bolts equally to raise the leveling legs (this will
lower the appliance). Recheck the level.
NOTE: Be sure to recheck the horizontal level of the top
drawer.
6. Be sure all four levelers are on the floor and supporting the
full weight of the refrigerator drawers.
8
05-May-2021 10:43:59 EDT | RELEASED
In some European factories the letter "W" of the part code mentioned herein will be automatically
replaced by the number "4000" (e.g. "W12345678" becomes "400012345678")