Apply plumber’s tape
PPR pipeline installation requires firm welding with special welding equipment.
This product should not be installed outdoors. It should be located away from
direct sunlight, heat sources, fuel oils, and chemicals.
Make sure to apply plumber’s tape evenly.
When tightening the hex nut with a wrench, make sure that other parts are not
turning with it.
After the filter is installed, check for any water leakage at the joints.
PRODUCT INSTRUCTIONS
After installation, open the inlet water main valve to allow water flow into the filter.
Before flushing, ensure that there is a reliable drainage system. You can also
flush the drain water in to a suitable container.
Turn the drain valve knob to flush the drain.
Press the on/off button to turn on the auto flushing module (optional) on, then
press the “drain” button to flush the drain.
Turn the scraper knob clockwise or counterclockwise 3 to 4 times while draining
the water to clean the filter mesh.
We recommend flushing at least once a week for 30 seconds each time,
depending on the quality of the incoming water.
To clean the filter cartridge after it has been used continuously for 8-12 months,
remove the stainless steel filter mesh and clean it with a brush or soak it in
vinegar. For best results, we recommend that it be professionally cleaned.