U-Line UHCP115-WS01A 1 Class 15" White Clear Ice Machine With Factory-Installed Drain Pump UHCP115WS01A

Product's Documents

Below are documents related to this product, you can read online or download:
User Manual Other Documents

User Manual

This is the main product document for model UHCP115-WS01A.

The file format is pdf, 19 pages, you can download this manual here .

background
QUICK START GUIDE
15“ Clear Ice Machines 115 V / 60 Hz
30682 Rev_A
background
QUICK START GUIDE
u-line.com
WELCOME TO U-LINE
Congratulations on your U-Line purchase. Your product comes from a company with over ve decades of premium modular ice
making, refrigeration, and wine preservation experience. U-Line continues to be the American leader, delivering versatility and
exibility for multiple applications including residential, light commercial, outdoor and marine use. U-Line’s complete product
collection includes Wine Captain® Models, Beverage Centers, Clear Ice Machines, Nugget Ice Machines, Crescent Ice Makers,
Glass & Solid Door Refrigerators, Drawer Models, Freezers, Combo® Models, and more.
U-Line has captivated those with an appreciation for the ner things with exceptional functionality, style, inspired innovations
and attention to even the smallest details. We are known and respected for our unwavering dedication to product design,
quality and selection. U-Line is headquartered in Milwaukee, Wisconsin and has shipped product to ve continents for over two
decades and is proud to have the opportunity to ship to you.
PRODUCT INFORMATION
Looking for additional information on your product? User Guides, Spec Sheets, CAD Drawings, Compliance Documentation,
and Product Warranty information are all available for reference and download at u-line.com.
PROPERTY DAMAGE / INJURY CONCERNS
In the unlikely event property damage or personal injury is suspected related to a U-Line product, please take the following
steps:
1. U-Line Customer Care must be contacted immediately at +1.414.354.0300.
2. Service or repairs performed on the unit without prior written approval from U-Line is not permitted. If the unit has been
altered or repaired in the eld without prior written approval from U-Line, claims will not be eligible.
GENERAL INQUIRIES
U-Line Corporation
8900 N. 55th Street
Milwaukee, Wisconsin 53223 USA
Monday - Friday 8:00 am to 4:30 pm CST
T: +1.414.354.0300
Email: sales@u-line.com
u-line.com
CONNECT WITH US
SERVICE & PARTS ASSISTANCE
Monday - Friday 8:00 am to 4:30 pm CST
T: +1.414.354.0300
Service Email: onlineservice@u-line.com
Parts Email: onlineparts@u-line.com
Designed, engineered and assembled in WI, USA
background
QUICK START GUIDE
u-line.com
This Quick Start Guide covers the basics of installation and general use of your product. For more details,
see the complete User Guide & Service Manual on u-line.com.
This product is eligible for an additional one-year warranty at no charge when you register your product on u-line.com.
See complete warranty for details.
Contents
1. Safety and Warning
2. Environmental Requirements
2. Electrical
3. Water Hookup
5. Drain
6. Door Swing
7. Door Adjustments
9. General Installation
10 . Integrated Panel Installation
11. Control Operation
11. First Use
12. Ice
13. Cleaning
16. Warranty
D
e
s
i
g
n
e
d
,
e
n
g
i
n
e
e
r
e
d
,
a
n
d
a
s
s
e
m
b
l
e
d
i
n
M
i
l
w
a
u
k
e
e
,
W
I
,
U
S
A
t
o
b
e
r
e
m
o
v
e
d
b
y
e
n
d
c
o
n
s
u
m
e
r
o
n
l
y
2
*
v
i
s
i
t
u
-
l
i
n
e
.
c
o
m
f
o
r
d
e
t
a
i
l
s
1 year + 1 with registration
*
background
QUICK START GUIDE
u-line.com
1
USER GUIDE
u-line.com
Safety and Warning
Safety and Warning
NOTICE
Please read all instructions before installing,
operating, or servicing the appliance.
Use this appliance for its intended purpose only and follow
these general precautions with those listed throughout this
guide:
SAFETY ALERT DEFINITIONS
Throughout this guide are safety items labeled with a
Danger, Warning, or Caution based on the risk type:
Danger means that failure to follow this safety
statement will result in severe personal injury or
death.
Warning means that failure to follow this safety
statement could result in serious personal injury
or death.
Caution means that failure to follow this safety
statement may result in minor or moderate
personal injury, property, or equipment damage.
This unit contains R600a (Isobutane) which is a
ammable hydrocarbon. It is safe for regular
use. Do not use sharp objects to expedite
defrosting. Do not service without consulting the
“R600a specications” section included in the
User Guide. Do not damage the refrigerant
circuit.
Service must be done by factory authorized
service personnel. Any parts shall be replaced
with like components. Failure to comply could
increase the risk of possible ignition due to
incorrect parts or improper service.
CALIFORNIA PROPOSITION 65
This product contains chemicals known to the
state of California to cause cancer and birth
defects or other reproductive harm.
www.P65warnings.CA.gov
This equipment is to be installed with adequate
backow protection to comply with applicable
federal, state and local codes.
This equipment is intended for the storage and
display of packaged products only.
If this refrigerator has a glass door, it is a display
refrigerator. Please see caution statement below:
This display refrigerator is not for the display of
potentially hazardous foods.
DANGER
!
DANGER
!
WARNING
!
CAUTION
!
DANGER
!
CAUTION
!
CAUTION
!
CAUTION
!
WARNING
!
background
QUICK START GUIDE
u-line.com
2
USER GUIDE
Electrical
u-line.com
Electrical
WARNING
!
SHOCK HAZARD — Electrical Grounding
Required. Never attempt to repair or perform
maintenance on the unit until the electricity has
been disconnected.
Never remove the round grounding prong from
the plug and never use a two-prong grounding
adapter.
Altering, cutting or removing power cord,
removing power plug, or direct wiring can cause
serious injury, fire, loss of property and/or life,
and will void the warranty.
Never use an extension cord to connect power to
the unit.
Always keep your working area dry.
NOTICE
Electrical installation must observe all state and
local codes. This unit requires connection to a
grounded (three-prong), polarized receptacle
that has been placed by a qualified electrician.
The unit requires a grounded and polarized 115 VAC,
60 Hz, 15A power supply (normal household current). An
individual, properly grounded branch circuit or circuit
breaker is recommended. A GFCI (ground fault circuit
interrupter) is usually not required for fixed location
appliances and is not recommended for your unit because
it could be prone to nuisance tripping. However, be sure
to consult your local codes.
See CUTOUT & PRODUCT DIMENSIONS for recommended
receptacle location.
Environmental Requirements
INDOOR UNITS
This model is intended for indoor/interior applications only
and is not to be used in installations that are open/exposed
to natural elements.
This unit is designed to operate between 50°F (10°C) and
100°F (38°C). Higher ambient temperatures may reduce
the unit’s ability to reach low temperatures and/or reduce
ice production on applicable models.
For best performance, keep the unit out of direct sunlight
and away from heat generating equipment.
In climates where high humidity and dew points are
present, condensation may appear on outside surfaces.
This is considered normal. The condensation will evaporate
when the humidity drops.
Damages caused by ambient temperatures of
40°F (4°C) or below are not covered by the
warranty.
OUTDOOR UNITS
This unit is designed to operate between 50°F (10°C) and
100°F (38°C). Higher ambient temperatures may reduce
the unit’s ability to reach low temperatures and/or reduce
ice production on applicable models.
For best performance, keep the unit out of direct sunlight
and away from heat generating equipment.
In climates where high humidity and dew points are
present, condensation may appear on outside surfaces.
This is considered normal. The condensation will evaporate
when the humidity drops.
Damages caused by ambient temperatures of
40°F (4°C) or below are not covered by the
warranty.
CAUTION
!
CAUTION
!
background
QUICK START GUIDE
u-line.com
3
USER GUIDE
Door Swing 1
u-line.com
SAFETY INSTALLATION & INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE
Water Hookup
PREPARE PLUMBING
The water valve uses a standard 1/4” (6.35 mm)
compression fitting.
U-Line recommends using accessory water hookup kit -
Part # 80-54674-00. The kit includes a 10’ (3 m) braided
flexible water supply line and a brass hose fitting.
WARNING
!
Prior to installation, determine if this product
contains a gravity style drain or factory installed
drain pump. Products without a drain pump may
only use a gravity style drain. Failure to connect
water supply or drain line connections properly
may result in water leakage, personal injury,
and/or property damage. Disconnect power and
turn off water to the unit before attempting to
alter these connections. These connections are
the responsibility of the owner and must be
connected per local plumbing code. If you are
uncertain of how to safely and properly install
this product, contact a licensed plumber.
Water Supply Connection
WARNING
!
Connect to potable water supply only.
CAUTION
!
Review, obey, and understand the local
plumbing codes before you install your unit.
Connect to the cold water supply. The water
pressure should be between 20 and 120 psi (138
and 827 kPa). The water line MUST
have a shut-
off valve on the supply line.
CAUTION
!
Do not use any plastic water supply line. The line
is under pressure at all times. Plastic may crack
or rupture with age and cause damage to your
home.
Do not use tape or joint compound when
attaching a braided flexible water supply line
that includes a rubber gasket. The gasket
provides an adequate seal – other materials
could cause blockage of the valve.
Failure to follow recommendations and
instructions may result in damage and/or harm,
flooding or void the product warranty.
CAUTION
!
Turn off water supply and disconnect electrical
supply to unit prior to installation.
Use caution when handling back panel. The
edges could be sharp.
1. Turn off water supply and disconnect electrical supply
to product prior to attempting installation.
2. Remove the grille/access panel in the front and the
back panel.
background
QUICK START GUIDE
u-line.com
4
USER GUIDE
Door Swing 2
u-line.com
SAFETY INSTALLATION & INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE
3. Locate water
valve in the front
of the unit and
thread water
supply line
through.
NOTICE
Route the water
supply line
through the unit so it does not come into contact
with any internal components other than the
solenoid valve. Normal operation creates some
vibration. A water supply line contacting an
internal component or cabinet wall can cause
excessive noise during operation or damage to
the line.
4. On the back panel,
break away filler feature
in bushing with flat
screwdriver.
5. Thread water line
through back panel hole
(with bushing) and
connect to cold water
supply line.
6. Turn on water supply and check for leaks.
7. Reinstall back panel and grille/front access panel.
8. Install retaining clip.
Remove
ZLWKɠDW
screwdrive
r
background
QUICK START GUIDE
u-line.com
USER GUIDE
Drain 1
u-line.com
SAFETY • INSTALLATION & INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE
Drain
Model numbers including “-00” or “-07” do not include a
factory installed drain pump.
Model numbers including “-40” or “-47” include a factory
installed drain pump.
DRAIN CONNECTION
CAUTION
!
If your U-Line unit did not come with a factory
installed drain pump you must use a gravity
style drain connection. For assistance in
determining if your unit has a pump please
contact U-Line. The floor drain must be large
enough to accommodate drainage from all
attached drains. Follow these guidelines when
installing drain lines to prevent water from
flowing back into the ice maker storage bin and/
or potentially flowing onto the floor, which may
result in personal injury or property damage.
Drain can NOT be located directly below the unit.
Unit has a solid base that will not allow the unit
to drain below itself.
There is a possibility that hose connections may
have loosened during shipment.
Verify all connections and fittings are free from
leaks.
GRAVITY DRAIN
A gravity drain may be used if:
Drain line has at least a 1" drop per 48" (approximately
2 cm drop per 100 cm) of run.
Drain line does not create traps and is vented per local
code.
1. Cut the pre-installed drain tube to length.
2. Connect to your local plumbing per the local code.
3. If necessary, insulate drain line to prevent
condensation.
CAUTION
!
Failure to connect water supply or drain line
connections properly can result in personal
injury and property damage. Gravity drain
connections must be routed downward from the
rest of the unit at the rate of 1/4" per foot (1 cm
per 50 cm).
Normal
Proper Drain
With Trap
Poor Drainage, Water Will Back Up
With Trap and Vent
Proper Drain
5
background
QUICK START GUIDE
u-line.com
USER GUIDE
Drain 2
u-line.com
SAFETY • INSTALLATION & INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE
FACTORY INSTALLED DRAIN PUMP
If your drain line will run up to a stand pipe, disposal or
spigot assembly, or does not otherwise meet the
requirements for a gravity drain, you may have ordered a
pre-installed U-Line P60 drain pump.
If you need to install a P60 drain pump into your unit, see
DRAIN PUMP section in the User Manual.
See below for typical installations requiring a drain pump.
NOTICE
The maximum lift for the P60 drain pump is
10 feet. This must be done as close to the rear of
the unit as possible.
Cold
Water
Hot
Water
Waste
Waste
6KXW2ɞ
Valve
Stand Pipe
P60 Pump Required
Air Gap
(Optional Hook-Up)
Cold
Water
Hot
Water
Waste
6KXW2ɞ
Valve
Disposal Assembly
P60 Pump Required
Waste
Cold
Wate
r
6KXW2ɞ
Valve
Hot
Water
Air Gap
(Optional Hook-Up)
Y-Branch Tailpiece
P60 Pump Required
USER GUIDE
Door Swing 1
u-line.com
SAFETY • INSTALLATION & INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE
Door Swing
Units have a zero clearance for the door to open 90°,
when installed adjacent to cabinets.
Stainless Steel and black and white models require 2-1/8"
(54 mm) door clearance to accommodate the handle if
installed next to a wall.
Integrated models require 1/4" (6 mm) clearance if
installed next to a wall. Allow for additional space for any
knobs or pulls installed on the integrated panel/frame.
Wall Wall
90
Door Swing
90
Door Swing
2-1/8" Min.
(54 mm)
1/4" Min.
(6 mm)
6
background
QUICK START GUIDE
u-line.com
7
Door Adjustments
HINGE COVER
Hinge cover included with the literature bag is optional.
To install hinge cover:
1. Press hinge cover squarely over hinge.
DOOR ALIGNMENT AND ADJUSTMENT
Align and adjust the door if it is not level or is not sealing
properly. If the door is not sealed, the unit may not cool
properly, or excessive frost may form in the interior.
NOTICE
Properly aligned, the doors gasket should be
rmly in contact with the cabinet all the way
around the door (no gaps). Carefully examine the
doors gasket to ensure that it is rmly in contact
with the cabinet. Also make sure the door gasket
is not pinched on the hinge side of the door.
To align and adjust the door:
1. Gently pry o hinge cover from top of unit.
2. Loosen (do not remove) top and bottom hinge screws
using a Torx T-25 screwdriver on the top and a 1/4”
socket on the bottom.
3. Align door squarely with cabinet.
4. Make sure gasket is rmly in contact with cabinet all
the way around the door (no gaps).
5. Tighten bottom hinge screws.
6. Tighten top hinge screws and replace hinge cover.
REVERSING THE DOOR
Location of the unit may make it desirable to mount the
door on the opposite side of the cabinet.
The hinge hardware will be removed and reinstalled on the
opposite side of the cabinet.
TO REVERSE THE DOOR
Remove arrow clips:
1. With a putty knife or other at tool, gently pry each
arrow clip from hinge mounting holes.
2. Set aside arrow clips to be reused on the opposite
side.
Remove top hinge and door:
1. Remove hinge cover from top of unit
2. Hold door to keep it from falling.
3. Remove top hinge from cabinet using a Torx T-25
screwdriver to remove three screws.
Hinge Cover
background
QUICK START GUIDE
u-line.com
8
1. Remove door by tilting forward and lifting door o
bottom hinge. Retain shoulder washers; they will be
reused.
2. Insert arrow clips into holes
Remove bottom hinge:
1. Remove bottom hinge from cabinet using a 1/4”
socket.
2. Remove corresponding screws on opposite side of
cabinet. On some models there may be a nut behind
one or both screws on either side.
Install bottom hinge:
Install two or three screws, depending on model. Replace
nuts if used.
PREPARE DOOR FOR REINSTALLATION
Rotate gasket
1. With a at tool, such as a
putty knife, gently pry up
beneath the gasket and
spacer until completely free
from the door surface.
2. Continue removing the
gasket by grabbing hold
and gently pulling outward,
exposing the gasket
channel.
3. Remove the 3 pieces of
gasket channel filler and
reinstall on the opposite end
of door.
4. Install gasket into channel,
beginning at one corner and
pressing in firmly.
5. Press down on middle
horizontal portion of gasket
until it adheres to the door
surface.
Install top hinge and door:
1. Remove pivot screw from hinge, ip hinge over, and
install the pivot screw in
the same hole from the
opposite surface.
2. Lift the door onto the
bottom hinge.
3. Align edge of the hinge with
the outer edge of the unit.
4. Tighten three screws and
replace hinge cover.
5. Replace hinge cover.
Align and adjust the door:
Align and adjust the door (see DOOR ALIGNMENT AND
ADJUSTMENT)
Top Hinge
Right Side
Top Hinge
Left Side
Pivot
Screw
Gasket Channel
Filler
Gasket With Spacer
Beneath
Gasket Channel
Press down firmly
Note: It may be
necessary to apply
a strip of two-sided
tape for a firm
adhesion.
background
QUICK START GUIDE
u-line.com
9
USER GUIDE
General Installation 1
u-line.com
SAFETY • INSTALLATION & INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE
General Installation
LEVELING INFORMATION
1. Use a level to
confirm the unit is
level. Level should
be placed along top
edge and side edge
as shown.
2. If the unit is not level, adjust the legs on the corners of
the unit as necessary.
3. Confirm the unit is level after each adjustment and
repeat the previous steps until the unit is level.
INSTALLATION TIP
If the room floor is higher than the floor in the cutout
opening, adjust the rear legs to achieve a total unit rear
height of 1/8" (3 mm) less than the opening’s rear height.
Shorten the unit height in the front by adjusting the front
legs. This allows the unit to be gently tipped into the
opening. Readjust the front legs to level the unit after it is
correctly positioned in the opening.
INSTALLATION
1. Plug in the power/electrical cord.
2. Gently push the unit into position. Be careful not to
entangle the cord or water and drain lines.
3. Re-check the leveling, from front to back and side to
side. Make any necessary adjustments. The unit’s top
surface should be approximately 1/8" (3 mm) below
the countertop.
4. Install the anti-tip bracket.
5. Remove interior packing material and wipe out the
inside of the unit with a clean, water-dampened cloth.
1
Turn to Adjust
USER GUIDE
Anti-Tip Bracket 1
u-line.com
SAFETY • INSTALLATION & INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE
Anti-Tip Bracket
1. Slide unit out so screws on top of unit are easily
accessible.
2. Remove the two screws from the opposite side of the
hinge assembly using a T-25 Torx driver (see below).
NOTE: 1224 models shown with four screw. 1215 models
only have three screws, but sa
me screws are used in both
applications.
3. Place bracket (part #14154) over holes and attach to
unit with two screws removed in step 2 using a T-25
Torx driver. Tighten screws fully.
4. Gently push unit into position. Be careful not to
entangle the electrical cord or water line, if applicable.
5. Check to be sure the unit is level from front to back
and side to side. Make any necessary adjustments.
The unit’s top surface should be approximately
1/8" (3 mm) below the countertop.
6. Secure bracket into adjoining surface.
background
QUICK START GUIDE
u-line.com
10
QUICK START GUIDE
u-line.com
SAFETY • INSTALLATION & INTEGRATION OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Integrated Panel Installation
1. Fully open door.
2. Starting at corner, pull
gasket away from door.
3. Continue to pull gasket
free from gasket channel.
4. Upon removal, lay gasket
down on a flat surface.
5. Partially loosen the 3 screws, securing the top hinge to
the cabinet.
6. Align the panel with the outside edge (opposite the
hinge) and high enough to align with the highest point
in the door.
7. Insert panel underneath top hinge and apply upward
pressure while bringing the lower portion of the panel
flush to the door inside the lower hinge. The panel will
fit snuggly.
8. Align door with cabinet. Tighten the top 3 screws,
securing the top hinge to the cabinet.
NOTICE
Due to differences in floor construction or
surrounding cabinetry, the panel may not
sit flush with the top of the door.
9. Secure integrated
panel to door using
clamps. A robust
tape may also be
used. U-Line
recommends the use
of bar clamps to
secure the panel to
the door. If using
tape, be certain the
tape will not damage
panel finish upon
removal.
10.Using a 7/64" (3 mm)
NOTICE
It is important to ensure that all drilled holes are
drilled to the correct depth in order to avoid
splits in the wood when hardwood is installed.
11.Locate 6 of the #6x 1-1/4" (32 mm) screws provided
with your unit.
Align Panel
Against
Door
Edge First
Align Top Of Panel With Highest Point Of Door
Door
Panel
Wood
Panel
Door
Bar
Clamp
Bar
Clamp
(Amended)
12.Using a Phillips screwdriver, place one screw into each
of the 6 pilot holes and screw down. Do not overtighten
screws.
13.Be sure the screws force their way past the opening on
the gasket channel and sit flush against the bottom of
the channel.
14.Remove clamps from door.
Integrated Panel
Integrated Panel
NOTICE
If panel requires additional adjustment after
removing clamps, slightly loosen each screw and
adjust panel as necessary. Tighten screws upon
completion.
15.Starting at the corners, re-install the gasket into the
gasket channel in the frame. Make sure the gasket is
fully seated. This may take some force.
drill bit, drill 6 pilot holes into the wood
panel 1/2" (12 mm) deep using the
holes in the door frame as a guide.
background
QUICK START GUIDE
u-line.com
11
Control Operation
CONTROL FUNCTION GUIDE
FUNCTION COMMAND NOTES
ON/OFF Press and release Unit will immediately turn On or OFF
Adjust ice thickness See “Ice” section
Enable Sabbath Mode
Press and hold for 5 seconds and
release
The
o
F /
o
C symbol will ash briey after 5 seconds.
Interior light and display will go dark and remain so
until user resets mode - unit continues to operate
Disable Sabbath Mode Press and release Display and interior light return to normal operation
Silent Mode (ice
production suspended for
3 hours)
Hold and
Display will countdown the hours: 3H, 2H, 1H
Clean Mode See “Cleaning” section
Showroom Mode Hold and for 5 seconds
The
º
F /
º
C symbol will ash. Display will be lit and
interior light will function. Unit will not cool. Repeat
command to return to normal operation
This unit is Star-K certied. See www.star-k.org for more details.
USER GUIDE
First Use
u-line.com
First Use
All U-Line controls are preset at the factory. Initial startup
requires no adjustments. See CONTROL OPERATION
section for more details.
NOTICE
U-Line recommends discarding the ice produced
during the first two to three hours of operation
to avoid possible dirt or scale that may dislodge
from the water line.
When plugged in, the unit will begin operating under the
factory default settings. If the unit was turned off during
installation, simply press and the unit will immediately
switch on. To turn the unit off, press and release.
USER GUIDE
Airflow and Product Loading 1
u-line.com
SAFETY INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Airflow and Product Loading
NOTICE
The unit requires proper airflow to perform at its
highest efficiency. Do not
block the front grille at
any time, or the unit will not perform as
expected. Do not install the unit behind a door.
background
QUICK START GUIDE
u-line.com
12
USER GUIDE
Ice 1
u-line.com
SAFETY INSTALLATION & INTEGRATION OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Ice
ICE CUBE THICKNESS ADJUSTMENT
NOTICE
Ice thickness adjustment should only be made
one increment at a time. Allow ice maker
production to stabilize for 24 hours before
rechecking ice thickness.
Ice is produced in layers resulting in a clear cube. Ice in
bin may develop surface frost which disappears when cube
is placed in liquid.
Ice cubes in any given batch will vary, so it is necessary
to choose cubes from the sample area for comparison
when making adjustments.
The ice cube thickness is factory set for best overall
performance. The factory setting is designed to maintain
an ice bridge of approximately 1/16" to 1/8" (1.6 mm to
3.2 mm) under normal conditions, resulting in a dimple of
approximately 1/4" to 1/2" (6.4 mm to 12.7 mm) in
depth. A fuller cube with less of a dimple results in a
thicker ice bridge. As the ice bridge becomes thicker, the
tendency for the cubes to stay together as a slab
increases. A bridge thicker than 1/8" (3.2 mm) may cause
cubes to overfill the ice bucket.
32 ice cubes are formed on a 4 x 8 slab during each cycle.
Each cycle takes approximately 15-20 minutes at the
default cube thickness (0).
Your clear ice machine is pre-set to produce ice between
the optimal dimensions illustrated below:
Ice thickness adjustments are made using the control
panel as follows:
1. To enter the thickness adjustment mode:
Press and hold for 5 seconds.
The display will switch to “0” to confirm the
thickness adjustment mode has been selected.
The factory setting is “0”. Us
e to raise the setting and
thicken the ice bridge, or to lower the setting to thin
the ice bridge.
Ice cubes in any given batch will vary, so it is necessary
to choose cubes from the sample area for comparison
when making adjustments.
DIMPLES
ICE BRIDGE
7/8"
(22 mm)
7/8"
(22 mm)
THINNER BRIDGE
THICKER BRIDGE
DEEPER DIMPLE
SHALLOWER DIMPLE
1/4" TO 1/2"
(6.4 mm to 12.7 mm)
DIMPLE
1/16" TO 1/8"
(1.6 mm to 3.2 mm)
ICE BRIDGE
Cube Details
Factory Default Setting - 0
< 0
SETTING
> 0
SETTING
background
QUICK START GUIDE
u-line.com
USER GUIDE
Cleaning 1
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Cleaning
EXTERIOR CLEANING
Vinyl Clad (Black or White) Models
Clean surfaces with a mild detergent and warm water
solution. Do not use solvent-based or abrasive cleaners.
Use a soft sponge and rinse with clean water. Wipe with a
soft, clean towel to prevent water spotting.
Clean any glass surfaces with a non-chlorine glass
cleaner.
Stainless Models
Stainless door panels, handles and frames can discolor
when exposed to chlorine gas, pool chemicals, saltwater
or cleaners with bleach.
Keep your stainless unit looking new by cleaning with a
good quality all-in-one stainless steel cleaner and polish
monthly. For best results use Claire
®
Stainless Steel
Polish and Cleaner. Comparable products are acceptable.
Frequent cleaning will remove surface contamination that
could lead to rust. Some installations may require cleaning
weekly.
Do not clean with steel wool pads.
Do not use stainless steel cleaners or polishes on
any glass surfaces.
Clean any glass surfaces with a non-chlorine glass
cleaner.
Do not use cleaners not specifically intended for
stainless steel on stainless surfaces (this
includes glass, tile and counter cleaners).
If any surface discoloring or rusting appears, clean it
quickly with Bon-Ami
®
or Barkeepers Friend Cleanser
®
and
a nonabrasive cloth. Always clean with the grain. Always
finish with Claire
®
Stainless Steel Polish and Cleaner or
comparable product to prevent further problems.
Using abrasive pads such as ScotchBrite™ will
cause the graining in the stainless steel to
become blurred.
Rust not cleaned up promptly can penetrate the
surface of the stainless steel and complete
removal of the rust may not be possible.
Integrated Models
To clean integrated panels, use household cleaner per the
cabinet manufacturers recommendations.
INTERIOR CLEANING
Disconnect power to the unit.
Clean the interior and all removed components using a
mild nonabrasive detergent and warm water solution
applied with a soft sponge or non-abrasive cloth.
Rinse the interior using a soft sponge and clean water.
Do not use any solvent-based or abrasive
cleaners. These types of cleaners may transfer taste
and/or odor to the interior products and damage or
discolor the interior.
CLEAR ICE MACHINE CLEANING CYCLE
Your U-Line clear ice machine has an automatic clean
alert function. Cleaning cycles should be run as notified.
Otherwise, to maintain operational efficiency the unit
should be cleaned every three months. Depending on
water conditions, more frequent cleaning may be
necessary. If the ice machine requires more frequent
cleaning, consult a plumber to test the water quality and
recommend appropriate treatment.
CAUTION
!
Wear rubber gloves and safety goggles and/or
face shield when handling Ice Machine Cleaner.
13
background
QUICK START GUIDE
u-line.com
USER GUIDE
Cleaning 2
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
NOTICE
Use only U-Line Ice Machine Cleaner (Part No.
37050, available from your dealer or direct from
your local parts distributor. To locate a parts
distributor near you, visit www.u-line.com. It is
a violation of federal law to use this solution in a
manner inconsistent with its labeling. Use of any
other cleaner can ruin the finish of the
evaporator and will void the warranty. Read and
understand all labels printed on the package
before use.
U-Line Ice Machine Cleaner is used to remove lime scale
and other mineral deposits. Refer to the following steps to
initiate the self-cleaning cycle.
CAUTION
!
Never use anything
to force ice from the
evaporator. Damage
may result.
1. Turn the ice
machine off and
allow any ice to melt
off of the
evaporator.
2. Remove all ice from the storage bin.
3. Remove evaporator cover.
4. Remove the standpipe by lifting it up while using a
slight back and forth motion to loosen it from the drain
hole. The water in the reservoir will flow down the
drain.
5. Re-install the standpipe into the water trough.
6. Clean the Interior Bin as follows:
Dilute one packet of CLR cleaner into two quarts of
water.
Using a sponge or cloth, clean interior of ice bin,
tubing and door. This cleaner will remove all mineral
deposits and other contaminants from the surfaces.
Using a bottle brush, clean out the trough drain tube
and pump tubing where needed.
7. Turn unit on by pressing .
8. Place the unit into CLEAN mode by holding for
5 seconds.
Evaporator cover
Standpipe
Evaporator
Water trough
Brush
14
background
QUICK START GUIDE
u-line.com
15
USER GUIDE
Cleaning 3
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
9. When water begins flowing over the evaporator
(approximately 3 minutes), pour 1 packet of CLR
cleaner into the water trough. The cleaning process will
last approximately 45 minutes.
10.Dilute 1 tablespoon bleach in 1 gallon of warm water.
Apply this solution to the entire inside of the storage
area. Then rinse thoroughly with water.
The unit will resume operation approximately 15 minutes
after the automated cleaning process is completed. The
water fill valve will energize, fill the water reservoir, and
shut-off after three minutes. The compressor begins to
operate and water flows over the evaporator assembly (ice
mold). Initially, the water flow may not be uniform,
causing uneven sized cubes or water to spill into the ice
storage bin. This is a normal situation that will correct
itself within the first 24 hours of operation.
NOTICE
Discard all ice produced in the first harvest.
Should power to the unit be interrupted during
the self-clean cycle, it will be necessary to
repeat the complete cleaning cycle after power
is restored.
REFRESH KIT
Due to variations in water quality or inadequate
maintenance your unit may become excessively coated in
lime scale or calcium. U-Line offers a cost effective
refresh kit which replaces many interior components and
will return your unit to like new condition. Refresh kits
may be ordered from your local distributor and installed
by your local service company. For information on your
local distributor or service company please visit
www.u-line.com.
background
16
Copyright © 2020 U-Line Corporation. All Rights Reserved. | Publication Number 30379 | 11/2020 Rev. O
U-Line Corporation (U-Line) Limited Warranty
One Year Limited Warranty
For one year from the date of original purchase, this warranty covers all parts and labor to repair or replace any part of the product that
proves to be defective in materials or workmanship. For products installed and used for normal residential use, material cosmetic defects
are included in this warranty, with coverage limited to 60 days from the date of original purchase. All service provided by U-Line under the
above warranty must be performed by a U-Line factory authorized servicer, unless otherwise specified by U-Line. Service provided during
normal business hours.
Two Year Limited Warranty (5 Class Product)
For two years from the date of original purchase, this warranty covers all parts and labor to repair or replace any part of the product that
proves to be defective in materials or workmanship. For products installed and used for normal residential use, material cosmetic defects
are included in this warranty, with coverage limited to 60 days from the date of original purchase. All service provided by U-Line under the
above warranty must be performed by a U-Line factory authorized servicer, unless otherwise specified by U-Line. Service provided during
normal business hours.
Available Second & Third Year Limited Warranty
In addition to the standard one and two year warranties outlined above, U-Line offers a one year extension of the warranties from the date
of purchase, free of charge. To take advantage of this extension, you must register your product with U-Line within 60 days from the date
of purchase at u-line.com and provide proof of purchase.
Five Year Sealed System Limited Warranty
For five years from the date of original purchase, U-Line will repair or replace the following parts, labor not included, that prove to be
defective in materials or workmanship: compressor, condenser, evaporator, drier, and all connecting tubing. All service provided by U-Line
under the above warranty must be performed by a U-Line factory authorized servicer, unless otherwise specified by U-Line. Service
provided during normal business hours.
Terms
These warranties apply only to products installed in any one of the fifty states of the United States, the District of Columbia, or the ten
provinces of Canada. The warranties do not cover any parts or labor to correct any defect caused by negligence, accident or improper use,
maintenance, installation, service, repair, acts of God, fire, flood or other natural disasters. The product must be installed, operated, and
maintained in accordance with your product’s User Guide.
The remedies described above for each warranty are the only ones that U-Line will provide, either under these warranties or under any
warranty arising by operation of law. U-Line will not be responsible for any consequential or incidental damages arising from the breach of
these warranties or any other warranty, whether express, implied, or statutory. Some states do not allow the exclusion or limitation of
incidental or consequential damages, so the above limitation or exclusion may not apply to you. These warranties give you specific legal
rights, and you may also have other rights which vary from state to state.
Any warranty that may be implied in connection with your purchase or use of the product, including any warranty of merchantability or any
warranty fit for a particular purpose is limited to the duration of these warranties, and only extends to five years in duration for the parts
described in the section related to the five year limited warranty above. Some states do not allow limitations on how long an implied warranty
lasts, so the above limitations may not apply to you.
The warranties only apply to the original purchaser and are non-transferable.
The second, third, and five year warranties cover products installed and used for normal residential or designated marine use only.
The warranties apply to units operated outside only if designed for outdoor use by model and serial number.
U-Line Commercial products are covered by the one year and 5 year limited warranties and are not eligible for the second and
third year limited warranties.
Replacement water filters, light bulbs, and other consumable parts are not covered by these warranties.
The start of U-Line’s obligation is limited to four years after the shipment date from U-Line.
In-home instruction on how to use your product is not covered by these warranties.
Food, beverage, and medicine loss are not covered by these warranties.
If the product is located in an area where U-Line factory authorized service is not available, you may be responsible for a trip
charge or you may be required to bring the product to a U-Line factory authorized service location at your own cost and expense.
Units purchased after use as floor displays, and/or certified reconditioned units, are covered by the limited one year warranty only
and no coverage is provided for cosmetic defects.
Signal issues related to Wi-Fi connectivity are not covered by these warranties.
For parts and service assistance, or to find U-Line factory authorized service near you, contact U-Line:
8900 N. 55
th
Street, Milwaukee, WI 53223 • u-line.comonlineservice@u-line.com+1.414.354.0300