GE - General Electric ZPK1 Monogram Ice Machine Drain Pump Kit

User Manual - Page 2

For ZPK1.

PDF File Manual, 4 pages, Download pdf file

Loading ...
-2-
STEP 1 Remove Original Parts
• Remove the 2 screws in the front lower access panel
and the 2 screws from the base grille area. Pull to
remove. Set aside screws and panel.
• Unplug power cord from rear cover.
• Remove screws holding the rear cover. Retain screws.
Carefully pull rear cover away from drain tube.
• Remove old drain tube and clamp attached to bin.
Discard the tube, retain the clamp for re-installation.
• Install the new drain tube with the new 5/8" clamp.
Remove Screws
Remove Screws
5/8" Hose Clamp
Drain Tube
(Bin to Pump)
STEP 2 Connect Electrical
A. Position pump at the right side, just outside of the
opening.
B. Remove clamp and screw attached to the icemaker
power cord. Attach the drain pump power cord to
the icemaker base with original clamp and screw.
C. Plug the icemaker power cord into the side of the
pump.
STEP 3 Install New Tubing
A. Attach new drain tube to pump check valve outlet
with new 1/2" hose clamp.
B. Attach vent tube to pump with new 1/2" hose
clamp.
C. Coil icemaker power cord into a 4" dia. coil and
secure with electrical tape. Place the coil over the
top of the pump.
D. Carefully slide the drain pump into the bottom
right side. The front tab on the pump should slip
into the rectangular slot on the icemaker floor. It
may be necessary to tip the pump slightly to engage
the tab.
Note: The pump must be in position before connect-
ing the bin drain tube. See Step 4.
Ground
Wire
Remove Clamp
and Screw
to Release
Icemaker
Power Cord
Pump
Power
Cord
Plug Icemaker
Power Cord
Into Pump
B
C
Position Pump
Just Outside
of Opening
A
Bin
Drain
Inlet
Vent Tube
Connection
Slide Pump Tab
Into Slot
D
C
Coil Icemaker
Power Cord
B
Drain Tube (Pump
to Household Drain)
A
Loading ...