Troubleshooting
Water sprays out the front
of the glasswasher.
Poor washing results.
Chemical supply container(s)
ll with water.
Splash curtain is missing, positioned
incorrectly or damaged.
Spray arm(s) are damaged or
missing.
Glass(es) interferes with splash
curtain.
Clogged spray arm(s) makes water
come out in wrong direction.
Water volume from wash and/or rinse
spray arm(s) low.
Water level in detergent tank low.
Water level oat ball stuck or lling
with water.
Water level switch defective.
Detergent and/or rinse-aid supply
low.
Wash pump and/or water valve(s)
and/or line strainers clogged or
defective.
Detergent tank temperature low.
Chemical injectors out of
adjustment.
Peristaltic tube(s) are
stretched or worn on the glasswasher
chemical pump(s).
Flow control washer
in cold water solenoid valve is
defective.
Problem Cause(s) Solution(s)
Re-install the splash curtain or
replace the splash curtain.
Replace spray arm(s).
Reload glass(es).
Clean the spray arm(s).
Clean spray arm(s).
Re-install drain/overow tube
in wash tank. Service Agent
must adjust water level switch
until water level is below top of
overow.
Clean oat ball, replace if lling with
water.
Authorized service agent may
replace switch.
Rell chemical supplies.
Authorized service agent may replace
wash pump and/or solenoid valve(s).
Clean line strainers.
Raise incoming water temperature
or adjust thermostat for
140°F/60°C in detergent tank.
Contact chemical supplier to
calibrate settings.
Inspect and replace tube(s).
Contact service agent to
repair solenoid valve.