Whirlpool CED8990XW1 electric commercial dryer

User Manual - Page 19

For CED8990XW1.

PDF File Manual, 64 pages, Download pdf file

Loading ...
Loading ...
Loading ...
ELECTRIC DRYER ELECTRICAL CONNECTIONS
Connection Options
Power Cord
4-wire receptacle (NEMA Type 14-30R)
3-wire receptacle (NEMA Type 10-30R)
Direct Wire
4-wire direct
3-wire direct
(127
Connecting 4-Wire Connection: Power Supply Cord
IMPORTANT: A 4-wire connection is required for mobile
homes and where local codes do not permit the use of 3-wire
connections.
Standard Power Supply Cord Connectors
Flangedspade connector Ring Connector
Connecting Ground and Neutral Wires
1. Remove center terminal block screw and the ground wire
by removing the external ground connector screw.
Connecting Direct Wire Ground
3. Connect ground wire (green or bare) with external ground
connector screw.
Connecting Remaining Wires
4. Connect remaining wires with outer terminal block screws.
2. Connect ground and neutral wire to center terminal block.
19
Loading ...
Loading ...
Loading ...