MCUF Series Vent-Free Firebox
FP2688
min floor combustible
Combustible
Material
6" Minimum
FP2688
Figure 5 -
Minimum Clearance above Combustible Flooring
14” Minimum
FP2689
min floor clear noncomb
Noncombustible
Material
May be Less
than 6"
FP2689
Figure 6 -
Minimum Clearances above Combustible Flooring with
Noncombustible Material Installed at Base of Fireplace

5. The canopy supplied with the unit
must be installed. If a combustible mantel is installed,
it must meet the clearance requirements as shown in
Figure 7a. However, if lower mantel height is desired,
refer to Figure 7b.
 The Vermont Castings Group Barrington Cabinet
Mantel Model series BWC300, BWC400 and BWC500 are
specially designed to comply with all mantel temperature
requirements. Any custom-built mantel must comply with all
clearance requirements shown in this instruction manual.
Figure 7a -
Mantel Clearances
FP2842
12”
8”
8”
14”
FP2691
mantel clear wide canopy
Figure 7b -
Mantel Clearances for Wide Prole Canopy Only
FP2691
45°
1”
256O
3”
5”
6”
56O
56O
56O
FP2692
mantel leg clearance
Fireplace
Finish Wall
Combustible
Material Area
Hood
FP2692
Figure 8 -
Mantel Leg Clearance