Installation instructions
Installing the Anti-Tip Bracket on the Floor
WARNING
To perform its intended function, the anti-tip bracket must be attached as instructed to the
concrete slab or wood sub-floor below any floor coverings (including cement board) on
top. Do not attach the anti-tip bracket directly to floor coverings such as ceramic/asphalt
tile or linoleum.
Floor covering
Sub-floor
Anti-tip bracket
Screws attached to sub-
floor below floor covering
Concrete anchors shown, do not
use for wood sub-floor
Four (4) plastic anchors are provided along with three sizes (4 each) of #8 or #12 Phillips
head screws for attaching the anti tip bracket to the floor. Use both the anchors and
four (4) of the screws when attaching the bracket to a concrete sub-floor. Do not use the
provided anchors when attaching to a wood sub-floor.
1. Determine the location of the range center line and front panel for the range’s final
position based on the Product Dimensions on page 5 and the actual cabinet/cutout
dimensions used for the installation.
2. Determine the required position of the anti-tip bracket, based on the diagram below.
Mark the four (4) mounting hole locations on the floor with a pencil.
3. Determine the screw size required. The minimum full thread depth (portion of screw
threaded into wood/slab) for wood is 3/8” (1 cm) and 5/8” (1.6 cm) for concrete. See
SCREW SIZE TABLE to select the correct screw size.