Installation requirements
Cabinet dimensions
All maximum and minimum dimensions and clearances shown in the diagrams below
must be maintained for safe operation.
Check the location where the range is to be installed. It should be placed away from
drafts that may be caused by doors, windows and heating and air conditioning outlets.
To reduce the risk of fire or personal injury from reaching over a hot appliance, avoid
cabinet installations directly above the range. If cabinet storage is to be provided, the
risk can be reduced by installing a range hood that projects horizontally a minimum of
5 inches beyond the bottom of the cabinets.
CUTOUT DIMENSIONS
Range Model A B C
DOP36M94DL*
42” (106.7 cm)*
36” (91.4 cm)**
36” (91.4 cm)**
36 1/8” (91.7 cm)***
33 1/2”
(84.8 cm)
DOP48M96DL*
54” (137.2 cm)*
48” (121.9 cm)**
48” (121.9 cm)**
48 1/8” (122.2 cm)***
9”
(22.9 cm)
* Recommended ** Minimum *** Maximum
Standard Cutout with Range Hood
A
B
B
C
13” (33.0 cm)
max.
5
Non-combustible
surface along back wall
recommended
Top of
finished
counter
10” (25.4 cm) min.
to combustible side
walls above the range
(both sides)
Suggested
location of
utilities
3
Grate
level
Note 2
Note 2
18” (45.7 cm)
4, 5
30” (76.2 cm)
min.
1
37 1/2”
(95.3 cm)
max.
Backsplash
3” (7.6 cm)
3/8" (1.0 cm) min.
flat countertop
overhang
non-combustible rear
wall recommended
10" (25.4 cm) min.
to combustible side
walls above the range
(both sides)
Cutout with Optional Downdraft Vent
(Top View)
Loading ...
Loading ...