TEMPERATURE CONTROL STANDARD
18
BATHROOM CONTROLLERS STANDARD
The Bathroom controller(s) allows the user to select the temperature setting for the hot water to be used in
the bathroom. They have a minimum temperature setting of 37°C and a maximum temperature setting of:
871 series 50°C
875 series 48°C
The Bathroom controllers operate in tandem. Whenever an operation is selected on one Bathroom controller,
it is also set on the other Bathroom controller. The Bathroom controllers automatically have priority if they are
on.
Important: It is important to turn on the Bathroom controller before opening a hot tap in the bathroom
(priority is automatically gained). If the Bathroom controller is not on and the Kitchen controller is on (has
priority), then it is possible to receive water at a temperature higher than expected from a hot tap in the
bathroom. This temperature could be up to:
871 series 50°C if a temperature limiting device is installed in the hot pipe to the
bathroom or up to 60°C AU or 55°C NZ if a temperature limiting device is
not installed.
875 series 48°C
Notes on the Bathroom controllers:
The controller cannot be turned on whilst a hot tap is open.
When a Bathroom controller is turned on, it gains priority from the Kitchen controller.
The Bathroom controller must be on in order to adjust the temperature setting on the Bathroom
controller.
The Kitchen controller can be turned off from a Bathroom controller.
Press and hold the on / off (
88
°C
) button on a Bathroom controller for three seconds.
This turns off all the controllers and the displays go blank.
If hot water is flowing from a hot tap, it will go cold.
Warning: It is advised to leave the Bathroom controller on after hot water usage is finished in the
bathroom. Turning off a controller in one bathroom will also turn off the controller in the other
bathroom. The Kitchen controller will gain priority if it is on and the temperature setting can be up to:
871 series 60°C AU 55°C NZ
875 series 48°C
If a hot tap is open in another bathroom, the water
will be delivered at up to 48°C for an 875 series
model, or up to 50°C for an 871 series model if a
temperature limiting device is installed in the hot
pipe to the bathroom or up to 60°C AU or 55°C
NZ if a temperature limiting device is not installed.
Rheem
°C
Bathroom Controller