Loading ...
Loading ...
Loading ...
9
ENGLISH
(Original instructions)
14 Wide mouth dust brush
BHFEV182B
BHFE
V182C
BHFEV
182CP
10 2 in 1 Accessory
11 Crevice tool √√
12 Accessory storage clip √√
13 Pet hair tool
u All available through service department
Cleaning and emptying the vacuum
Filter sense
Whenever a lter is Blocked and needs cleaning, the red
lter LED (3) in the chassis will illuminate.
Filter agitator (Fig. H)
With the lift away dust canister (6) off the chassis (17) ,
rotate the lter agitator wheel 5 - 10 times to remove exces-
sive dust from the lter thus increasing its performance.
Note: It is recommended that you agitate when the unit is
emptied and the prelter removed.
Note: Maximum dust collection will only be obtained with
clean lters and an empty dust canister.
If dust begins to fall back out of the product after it is switched
off, this indicates that the dust canister is full and requires
emptying.
To empty the dust canister (Fig. I, J)
u Lift and remove the lift away dust canister (6) from the
chassis (17) as shown in gure I.
u Place the dust canister over a dust bin and press the
dust canister lid release button (6a) to empty the dust
canister as shown in gure J.
u Close the dust canister lid (7), until it “clicks” rmly
into position.
u Install the lift away dust canister (6) back onto the
chassis (17).
Removing pre-lter (Fig. K)
u Lift and remove the lift away dust canister (6) from the
chassis (17) as shown in gure I.
u Place the dust canister over a trash bin and press the
dust canister lid release button (6a) to empty the dust
canister as shown in gure J.
u Use your index nger and thumb to pinch the pre-lter
(18), pull the pre-lter (18 ) from the dust canister (6) as
shown in gure K.
Note: The lter housing ts snuggly in the dust canister
and may be difcult to remove at rst.
u Empty the dust canister.
u Install the pre-lter (18) into the dust canister (6)
ensuring the dust canister tab (20) aligns with the prelter
slot (19) as shown in gure K.
u Install the dust canister onto the vacuum, until it “clicks”
rmly into position.
Removing lter (Fig. L)
u Lift and remove the lift away dust canister (6) from the
chassis (17) as shown in gure I.
u Place the dust canister over a trash bin and press the
dust canister lid release button (6a) to empty the dust
canister as shown in gure J.
u Grasp the agitator wheel housing (21) and pull up
to remove.
u Remove the lter (22), from the agitator wheel housing
(21) as shown in gure L.
u Shake off or lightly brush any loose dust from the lter.
u Install the the lter (22), into the agitator wheel
housing (21).
u Install the agitator wheel housing (21) onto the dust
canister, until it “clicks” rmly into position.
Cleaning the lters
u Once the lter and pre-lter are removed from the dust
canister shake off or lightly brush any loose dust from
the pre-lter and lter.
u Rinse out the dust canister (6) with warm soapy water.
u Wash the lters with warm soapy water.
u Ensure the lters are completely dry (24 hrs) before
retting.
u Follow instructions in the “Removing pre-lter and
Removing lter” sections for assembly instructions.
Note: Maximum dust collection will only be obtained with
clean lters and an empty dust canister.
If dust begins to fall back out of the product after it is
switched off, this indicates that the dust canister is full
and requires emptying or that there is a blockage somewhere.
u Wash the lters regularly using warm, soapy water and
ensure that it is completely dry before using again. The
cleaner the lter is, the better the product will perform.
u It is very important that the lters are completely dry
and correctly in position before use.
Removing and clearing the rotary brushes
(Fig. M)
Warning! To reduce the risk of injury from moving parts,
disconnect battery before cleaning or servicing.
u To remove the rotary brush (23) from the oor head (8)
depress the release button (24) as shown in gure M.
u Lift the rotary brush from its locked position.
u The rotary brush (23) can now be removed.
u Clean the rotary brush, and reinstall. Ensure it is secured
in its locked position before operating.