Operating the appliance
TR5000R – 6 720 876 032 (2017/06)
6
4 Operating the appliance
4.1 Switching the appliance on and off
The continuous-flow heater switches on and heats the water when the
warm water tap is opened. It switches off again if the water tap is closed.
4.2 Setting the water temperature
Turn the rotary selector switch.
Use the continuously-variable switch to set the desired temperature for.
Note: If a thermostatic-regulating mixer tap is used for high
temperatures or for large water volumes, then it is recommended
that the setting “Bathing” or “Rinsing” be selected.
Increasing the water temperature
If a higher temperature is not obtained when the warm water tap is fully
opened, then this is because more water is flowing than the continuous-
flow heater’s power capacity can heat.
If this happens, then slightly close the warm water tap.
Decreasing the water temperature
Turn the rotary selector switch to a lower level e. g. “Washing hands” .
Note: If the temperature of the water supplying the appliance changes,
then the output temperature of the water leaving the tap also changes
correspondingly.
4.3 Status display
4.4 Startup after power failure
Open the warm water tap fully and allow water to flow until it is warm.
4.5 Using the appliance after switching
off the water supply
Switch off the appliance (unscrew the fuse in the fusebox).
Open the warm water tap and keep it open until the air has been
completely forced out of the water pipe.
Switch the fuse back on again.
Open the warm water tap fully and allow water to flow for at least
one minute.
Only then (for safety reasons) will the appliance begin to heat.
The appliance is now ready to operate.
4.6 Saving energy
Set the desired water temperature directly on the appliance.
The appliance is operated economically when set to approximately
40 °C (rotary selector switch: “Showering” ).
Note: Mixing in of cold water at the faucet/fitting consumes unnecessary
water and energy.
This also accelerates calcification (scaling) of the appliance. Therefore,
please always set the desired temperature directly on the continuous-
flow heater.
4.7 Winter operation
Note: It is possible in winter that the supply temperature of the water
is reduced and the required outlet temperature is no longer achieved.
Reduce the water flow on the taps until the desired water
temperature is reached.
5 Cleaning
Only wipe off the appliance using a moist cloth.
Do not use acidic or abrasive cleaning materials.
Do not use a steam cleaner.
6 Customer Service
We ask you to always provide the E-No. and the FD-No. of your appliance
when calling in a customer service engineer. You will find the numbers on
the ratings plate on the inner side of the front flap.
The contact information for your country can be found on the last pages
of these instructions.
7 Environmentally-friendly disposal
Dispose of the packaging in an environmentally sound manner.
Subject to change without notice.
Washing hands Showering
Bathing Rinsing
LED Appliance status
Off Off
Lights green On
Flashes green (1/s) The set temperature is not obtained; the rate
of water flow is too high for appliance rating
(the appliance has reached the power limit).
See “A fault, what to do?”
Flashes green (2/s) Cold-water rinse-through phase
Flashes red See “A fault, what to do?”
This appliance is labelled in accordance with European
Directive 2012/19/EU concerning used electrical and
electronic appliances (waste electrical and electronic
equipment – WEEE).
The guideline determines the framework for the return
and recycling of used appliances as applicable
throughout the EU.
Please ask your specialist retailer about current disposal
facilities.
Loading ...
Loading ...
Loading ...