www.factorybuysdirect.com
200253-01A12
INSTALLATION
BUILT-IN FIREPLACE INSTALLATION
Figure 9 - Rough Opening for Wall
Installation
Figure 7 - Clearance to Combustibles
Figure 8 - Fireplace Clearances
3/4" Clearance to Facia
Note: Height of fireplace opening on facia to be 23
1
/
4
"
1
3
/
8
" Clearance to Sides, Back and Top
27
3
/
4
"
28
3
/
4
"
13"
16"
19"
21"
10"
8"
6"
2
1
/
2
"
Side of
Firebox
Mantel
Shelf
Note: All vertical
measurements
are from top of
fireplace
opening to
bottom of
mantel shelf. All
measurements
are in inches.
23.25"
12.75"
28.75"
WARNING: Do not allow any
combustible materials to overlap
the rebox front.
WARNING: Do not allow
combustible or noncombustible
materials to cover any necessary
openings like louvered slots.
WARNING: Never modify or
cover the louvered slots on the
front of the rebox.
Built-in installation of this replace involves
installing replace into a framed-in enclosure.
This makes the front of the replace ush
with wall. If installing a built-in mantel above
the replace, you must follow the clearances
shown in Figure 7.
NOTICE: Surface temperatures
of adjacent walls and mantels
become hot during operation.
Walls and mantels above the
replace may become hot to the
touch. If installed properly, these
temperatures meet the require-
ment of the national product
standard. Follow all minimum
clearances shown in this manual
(see Figure 8).
1. Frame in rough opening. Use dimensions
shown in Figure 9 for the rough opening.
If installing in a corner, use dimensions
shown in Figure 10 (page 13) for the rough
opening. The height is 26
1
/
2
", which is the
same as the wall opening above.
2. Carefully set replace in front of rough
opening with back of replace inside wall
opening.