Sierra Flame BENNETT45LP Bennet Series Direct Vent Liquid Propane Fireplace

User Manual - Page 6

For BENNETT45LP.

PDF File Manual, 57 pages, Read Online | Download pdf file

BENNETT45LP photo
Loading ...
Loading ...
Loading ...
Page 6 of 57
1.0 INTRODUCTION
1.1 SPECIFICATIONS
TABLE 1
ITEM
NATURAL GAS (NG)
PROPANE (LP)
MAXIMUM INPUT: Hi
30,000 Btu/hr (8.79 kW)
27,000 Btu/hr (7.91 kW)
MINIMUM INPUT: Lo
22,000 Btu/hr (6.45 kW)
19,500 Btu/hr (5.71 kW)
MANIFOLD PRESSURE:
COLLECTEUR DE PRESSION:
3.5” w.c. (0.87 kPa) 10.0” w.c. (2.49 kPa)
GAS INLET SUPPLY PRESSURE:
ENTREE DE PRESSION
Minimum: 5.0” w.c. (1.2 kPa)
Minimum: 7.0” w.c. (1.74 kPa)
Maximum: 13.5” w.c. (3.4 kPa)
Maximum: 13.5” w.c. (3.4 kPa)
ORIFICE SIZE: @ 0-2000
FORMAT D'ORIFICE:
2 X # 49 DMS 2 X # 58 DMS
AIR SHUTTER
VOLET DE L’AIR
OPEN 1/8min
(3.175mm)
FULLY OPEN
CONTROL VALVE TYPE:
TYPE DE SOUPAPE
Skytech AF-40004 Skytech AF-40004
VENTING
ÉVACUATION
2-ply aluminum vent, Selkirk,
Duravent , Security Venting,
ICC Venting or
Metal-Fab Venting
2-ply aluminum vent, Selkirk
Duravent, Security Venting,
ICC Venting or
Metal-Fab Venting
FAN
VENTILATEUR
Variable Speed (110 Volt / 60 Hz) Variable Speed (110 Volt / 60 Hz)
THIS APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON THE RATING
PLATE.
CET APPAREIL DOIT ÊTRE UTILISÉ UNIQUEMENT AVEC LE TYPE DE GAZ INDIQUÉ SUR LA
PLAQUE SIGNALÉTIQUE.
largeur et la profondeur de la cheminée.