Service and Installation Manual
10
DANGER
needed
Never use a high-pressure water wash for this cleaning procedure as water can
damage the electrical components located near or at the condenser coil.
MAINTENANCE
1.3 CLEAN THE GASKET
- The door gasket should be cleaned frequently to maintain proper sealing
1.4 CHECK AFTER CLEANING
- Check the unit again for safety
- Check that the unit is operating properly
2. The lid may be cleaned in the same way as the cooler.
3. If a condenser and associated fan are fitted at the back bottom of the cooler, they can gather dust and dirt.
If cleaning is necessary, they should be vacuumed with a soft brush.
4. Please note that the parts behind the protective grill can be hot and rotating.
5. POWER CORD
5.1
- Please make sure that the power cord is connected to the proper voltage
The power cord must be connected to a protected circuit with the correct voltage
and amperage
- Turn ʻoffʼ the power switch before disconnecting the power cord, whenever
performing maintenance functions or cleaning the refrigerated cabinet
- Compressor warranties are void if compressor burns out due to improper voltage
5.2. RE-STARTING
- If disconnected, wait for 5 minutes before re-starting