PLAN VENT SYSTEM
Choose your exhaust installation type
Recommended exhaust installations
Typical installations vent tile dryer from the rear of tile dryer. Other installations are possible.
A ¸
B
.........i..............................F
A. Dryer
B. Elbow
C. Wall
D. Fxhaust hood
E. Clamps
I. Rigid metal or flr,xible metal vent
G. V_'nt I_'ngth necessary to connect elbovw
H. Exhaust outlet
Standard exhaust installation with rigid metal or flexible metal vent
Alternate installations for close clearances
Venting systems come in many w_rieties. Select the type best for your installation. |WO close-
clearance installations are shown, Refer to the manufacturer's instructions.
f .........
"""--i ..... "--t......
A B
A. Over-the-top installation (also available with one
offset elbow)
B. P_'_igcopeh_stallation
NOTE: The following kits for close clearance alternate installations are available for purchase.
Please see the "Assistance or Service" section of this manual to order.
Over-the-lop Installation:
Part Number 4396028
Periscope Installation (For use with dryer vent to wall vent mismatch):
Part Number 4396037 - 0" (0 cm) to 18" (45.72 cm) mismatch
Part Number 4396011 - 18" (45.72 cm) to 29" (73.66 cm) mismatch
Part Number 4396014- 29" (73.66 cm) to 50" (127 cm) mismatch
Special provisions for mobile home installations
[he exhaust vent must be securely fastened to a noncombustible portion of the mobile home
structure and must not terminate beneath the mobile home. Terminate the exhaust vent
outside.