Broan EBS1304SS 30 Inch Under Cabinet Range Hood with 3Speed

User Manual - Page 18

For EBS1304SS.

PDF File Manual, 80 pages, Read Online | Download pdf file

Loading ...
Loading ...
Loading ...
- 18 -
2. CONNECT ELECTRICAL:
Power Supply Connection:
For connection to the power supply refer to Fig.7:
BLACK = L line
WHITE = N neutral
GREEN/YELLOW = G ground
- A double-pole switch properly rated must be
installed to provide the range hood power supply
disconnection.
- Connect the electrical conduit to the Field Wiring
Compartment using listed conduit ttings.
- Carry out the power supply connection in
accordance with the national electric code, ANSI/
NFPA 70-1999.
5. Insert the wires into the box, then close the box
cover, securing it using the s c re w s t h a t w er e
previously removed.
The appliance should be installed at a minimum
height of 26" up to a maximum height of 32" for
optimal performance. If a connection ductwork
composed of two parts is used, the upper part
must be placed outside the lower part. Do not
connect the range hood exhaust duct air to the
same duct air used to exhaust hot air or fumes from
other appliances other than electrical.
In the FILTERING version it is necessary to
apply a metal air exhaust tube M (Fig.8), with a
minimum length of 15", connected to the ange of
the collector. It must be positioned vertically and
fastened to a specic opening made on the top
part of the cabinet.
1
4
A
3
M
2
Fig.7
Fig.8
Min 26" - Max 32"
36"
3. CONNECT THE DUCTWORK: