Installation
*INSTALLATION*
29
a
Extraction
b
Recirculation
c
Ventilation grille positioned at the top for recirculation
de
(Only d is required for recirculation mode cooker hoods). The shaded area
represents the wall or ceiling area for the ducting cut-out and for the
connection socket. Recirculation cooker hoods only need a connection
socket to be fitted.
Connection for air extraction 150 mm
Safety distance between hob and cooker hood (S)
When planning the installation height of your cooker hood, the minimum safety
distance between the top of a cooker or hob and the bottom of the cooker hood
is as follows, unless a greater distance is specified by the manufacturer of your
cooking appliance.
See “Warning and Safety” instructions for further information.
Cooking appliance Minimum distance S
Electric hob 450mm
Electric grill, deep fat fryer (electric) 650mm
Multi-burner gas hob,
total output 12.6 kW, no burner > 4.5 kW
650mm
Multi-burner gas hob,
total output > 12.6 kW and 21.6 kW,
no burner > 4.8 kW.
760mm
Multi-burner gas hob,
total output > 21.6 kW,
or multi-burner gas hob where one burner > 4.8 kW.
Not possible
Single burner gas hob, output 6 kW. 650mm
Single burner gas hob, output > 6 kW and 8.1 kW. 760mm
Single burner gas hob, output > 8.1 kW Not possible