Ashley AP5501S E Heater

User Manual - Page 6

For AP5501S.

PDF File Manual, 56 pages, Download pdf file

Loading ...
Loading ...
Loading ...
6
© 2021 United States Stove Company
INSTALLATION
IMPROPER INSTALLATION
The use of other components other than stated
herein could cause bodily harm, heater damage,
and void your warranty. The manufacturer will not
be held responsible for damage caused by the
malfunction of a stove due to improper venting or
installation.
FLOOR PROTECTION
This heater must have a non-combustible oor
protector (UL1618 ember protection) installed
beneath it if the oor is of combustible material.
US - Floor protector should be UL listed or equal too,
needs to extend 6” to the front, 6” to each side, 1” to
the rear of the unit. Under and 2” beyond each side
of the cleanout tee if an interior vertical installation.
Canada - Floor protector should comply with CAN/
ULC standards. Needs to extend 18” to the front, 8”
beyond each side of the unit.
A Back to Stove
U.S.A 1” 26 mm
CAN 8” 204 mm
B Side to Stove
U.S.A 6” 153 mm
CAN 8” 204 mm
C Front to Stove
U.S.A 6” 153 mm
CAN 8” 204 mm
D Back to Flue 2” 51 mm
CLEARANCES
Your pellet stove has been tested and listed
for installation in residential, mobile home in
accordance with the clearances given below. For
safety reasons, please adhere to the installation
clearances and restrictions. Any reduction in
clearance to combustibles may only be done by
means approved by a regulatory authority.
E Side Wall to Stove 10” 254 mm
F Side Wall to Vent Pipe 11.5” 292 mm
G Back Wall to Stove 11.88” 302 mm
H Back Wall to Vent Pipe 3” 76 mm
J Ceiling to Floor 84” 2134 mm
K Ceiling to Stove 48.88 1242 mm
L Side Wall to Stove 7.5” 191 mm
M Side Wall to Vent Pipe 11.25” 286 mm
N Back Wall to Vent Pipe 3” 73 mm
OUTSIDE AIR SUPPLY  

Depending on your location and home
construction, outside air may be necessary for
optimal performance. Your stove is approved to be
installed with an outside air intake (69FAK) which
is necessary for a mobile home. You can purchase
the 69FAK through your heater dealer. Installation
instructions are supplied with the air intake kit.
FOR CUSTOMER SERVICE CALL: 800-750-2723 EXT 5050