Loading ...
Loading ...
Loading ...
LP/PROPANE GAS CONVERSION
This appliance can be used with Natural Gas or LP/Propane gas. It is shipped from
the factory for use with natural gas. A kit for converting to LP gas is supplied with
your cooktop. The kit is marked “FOR LP/PROPANE GAS CONVERSION”.
When the cooktop is converted for liquid petroleum (LP) gas, the LP gas supply is
cooktop regulator.
with the kit instructions and all local codes and requirements. Failure to follow
performing this work assumes responsibility for the conversion.
24" Burner and Orice Characteristic Table
Burner Position
Orice Gas Pressure Rate
Diam. (mm) Type [i.w.c.] [BTU/h]
Front R 1.10 NG 4" 5000
0.70 LP (Propane) 10" 5000
Semi-Rapid Rear L 1.29 NG 4" 6900
0.80 LP (Propane) 10" 6500
Triple Front L 0.99 x 5 NG 4" 17400
0.56 x 5 LP (Propane) 10" 15000
Semi-Rapid Rear R 1.29 NG 4" 6900
0.80 LP (Propane) 10" 6500
NOTE: The triple burner has only two injectors, one injector mounted in the center
and one mounted below the cover plate. To access the second injector, remove the
two screws and the cover plate.
a
a
a
Opening in grate for wok ring (provided) is located over left front burner.