Troubleshooting
English
TROUBLE/SYMPTOM POSSIBLE CAUSES ACTION
No Output
120Vac supply not connected
Connect power supply
Check AC distribution panel for proper
operation
External Fuses Blown
Check for reverse polarity
Replace fuses with same type and rating
Short Circuit Trace RV circuits for possible fault
Unit has shutdown due to
overheating
Check air flow
Allow unit to cool
Unit has shutdown due to over
voltage
Check input voltage
Correct input voltage
External Fuses
Blown
Reverse polarity hook up
Correct hook up and replace fuses with same
type and rating
Converter cycles on
& off
Compartment gets too hot or
output current is out of the rated
current
Check air flow to the converter
Improve ventilation to the compartment
Check the load capacity
Low Output
Excessive load for converter
Reduce load requirements or install larger
converter
Bad Battery Cell(s) Replace battery
Intermittent or
no Output on
Generator, works on
Shore Power
Unit has shutdown due to over
voltage
Add another load to the generator. This may
reduce the “spikes” to an acceptable level
Some generators exhibit
excessive voltage spikes on the
AC power output. This may cause
the over voltage protection to
shut the unit down
Contact generator manufacturer for possible
defect in the generator