Maintenance and Service
WARNING! Hot Surfaces!
GlassandothersurfacesarehotduringoperationANDcool
down. DO NOTcleanreplaceuntilitiscooled.
Installation and repair should be done by a qualied
service technician only. The replace should be inspected
before use and at least annually by a professional service
person.
The following tasks may be performed annually by the
homeowner. If you are uncomfortable performing any of
the listed tasks, please contact your dealer for a ser-
vice appointment.
A. Chimney Inspection
Frequency: As necessary; at least annually before
lighting replace, or once every two months during
heating season.
By: Homeowner/Chimney Sweep
Confirm that termination cap remains clear and
unobstructed.
Inspect for blockages such as bird nests, leaves, etc.
Inspect for corrosion or separation.
Inspect for creosote and remove as needed, at least
every two months during the heating season.
Inspect the system at the replace connection and
at the chimney top.
In the event of a chimney re, Vermont Castings Group
recommends replacement of the chimney and inspec-
tion of the adjacent structure to the provisions of NFPA
Level III inspection criteria.
WARNING! Risk of Asphyxiation and Fire! Annual
inspectionbyqualiedtechnicianrecommended.
Check:
• conditionofdoors,surroundsandfronts
• conditionofglassandglassassembly
• obstructionsofcombustionandventilationair
• obstructionsofterminationcap
Clean:
• glass
• airpassageways,grilles