28
676
Specifications
MICROPHONE INPUT
Connector: Female XLR (Pin 2 Hot)
Type: Transformer balanced/unbalanced, RF filtered
Impedance: 1.9 kΩ
CMRR: >85 dB from 20 Hz to 3 kHz, >70 dB from 3 kHz to 20 kHz
INSTRUMENT INPUT (FRONT PANEL)
Connector: Tip-Sleeve ¼” Jack
Type: Unbalanced
Impedance: 500 kΩ
Maximum Input Level: +21 dBu unbalanced
PREAMP INSERT
Connector: Tip-Ring-Sleeve ¼”, RF filtered
Type: Unbalanced, Tip = send, Ring = return
Impedance: 50 Ω (send), 20 kΩ (return)
LINE OUTPUTS (PREAMP & COMPRESSOR/LIMITER)
Connector: Male XLR and Tip-Ring-Sleeve ¼” (Pin 2 and Tip hot)
Type: Servo-balanced/unbalanced
Impedance: Balanced 30 Ω, unbalanced 15 Ω
Maximum Output Level: > +21 dBm (into a 600 ohm load)
COMPRESSOR SIDECHAIN INSERT
Connector: Tip-Ring-Sleeve ¼”, RF filtered
Type: Unbalanced, Ring = output, Tip = input
Impedance: 1 kΩ (output), 50 kΩ (input)
VACUUM TUBE
Type: 12AU7A / ECC82
Grid Power Supply: +250V DC
Heater Power Supply: +12V DC
SYSTEM PERFORMANCE
Frequency Response: Mic Input: 20 Hz to 50 kHz, +0/-1dB, 40 dB gain
Instrument Input: 30 Hz to 70 kHz, +0/-1dB, unity gain
THD + Noise: Mic In to Line Out: 0.25% typical at 0 dBu out, 1 kHz, 40 dB gain
Instrument In to Line Out: 0.2% typical at 0 dBu out, 1kHz, unity gain
Equivalent Input Noise: Typically > -123 dBu with a 150 Ω source load, 22 Hz to 22 kHz
Noise Floor: Mic Insert to Comp Output: <-93 dBu, unity gain, EQ flat and no gain reduction
Operating Temperature: 0º to 40º C (32º to 104º F)
PREAMP FUNCTION SWITCHES / CONTROLS
Instrument Input: Selects between microphone XLR input and front panel ¼” instrument input
+48V: Sends +48 VDC through 6.81 kΩ resistors to pins 2 and 3 of the microphone input
20 dB PAD: Attenuates the microphone input by 20 dB
Polarity Invert: Reverses pins 2 and 3 of the microphone input XLR
80 Hz Low Cut: Enables an 80 Hz, 12 dB/octave high-pass filter in the microphone and instrument signal path
GAIN Control Range: - to +55 dB for Microphone Input
- to +40 dB for Instrument Input
Post Tube Attenuation: - to 0 dB
Peak Indicator: Illuminates RED when the Preamp is within 3 dB of clipping