If the supply cord is damaged, it must be replaced
by an authorized Gerni distributor or similar qualied
person in order to avoid a hazard.
No actions needed for adjusting machines marked
with dual voltage and frequency.
Supervise children not to play with the machine.
The operator and any one in the immediate vicinity
of the site for cleaning should take action to pro-
tect oneself from being struck by debris dislodged
during operation.
Always wear safety boots, respiratory mask, ear
protection, goggles and protective clothing during
operation.
The high pressure generated by the machine is a
particular source of danger. Hold the spray lance
rmly with both hands. The spray lance is a󰀨ected
by a kickback force and a sudden torque during
operation.
See PART 3:3 for the actual size of the kickback
force.
During transportation: Position the machine hori-
zontally on the backside and secure with straps.
High pressure washers shall not be used nor main-
tained by children or untrained people or people with
reduced physical, sensory or mental capabilities
or lack of experience and knowledge.
Part 2:3 - User Guide
Provides a general overview of the machine and
operation elements along with illustrated sections on
preparation, operation, water connection, storage,
and user maintenance.
A Unpacking and preparing for use
Follow illustrations in A.
B Connection to potable water mains
High pressure washers are not suitable for con-
nection to the potable water mains. Always check
national regulations before connecting the machine
to potable water mains and use a back-ow preventer
if required.
Use ½" garden hose, 10-25 m.
Follow illustrations in B.
C Connection to other water sources
You can connect the machine to e.g. rain water ves-
sels, rivers, lakes and cisterns etc. and operate it in
suction mode. Follow illustrations in C.
D Pairing of spray handle and machine
Not relevant.
E
Leaving the machine unattended > 5 min.
See listed warnings. Follow the illustrations in E.
F After use and storage
After use always: Turn o󰀨 the machine. Empty ma-
chine and accessories of water to avoid frost damage.
Remove the plug from socket. Disconnect water inlet
hose. Wind up electrical cable and high pressure
hose to avoid damage of cable, high pressure hose
and ttings. Storage of machine shall be frost free.
Follow illustrations in F.
G Maintenance, inspection and repair
Maintenance of the machine should always be done
when starting up after long time of storage.
Before use, always inspect the machine and
equipment for damages. In case of damages, act
according to listed warnings.
Do not attempt any maintenance not described
in the instructions. If the machine refuses to start,
stops, pulsates, pressure uctuates, motor buzzes,
fuse blows or no water comes out, check Part 3.3
Troubleshooting.
User maintenance according to illustrations in G.