10
Step 5: Positioning The System
The RO system can stand on the ground or be secured to the wall. The storage tank may be laid on its side
if needed. This position does not affect the tank’s performance. If there is not enough room near the RO
system, you can put the tank away from the system, up to about 20 feet horizontal without much pressure
loss.
Step 6: Connecting The System
There are 4 connections:
Point A to X: Connect RO to COLD water supply- 3/8” Red tubing.
Point G to Y: Connect product water from Last-stage post carbon filter to tank- 3/8” Yellow tubing *.
Point H to Z: Connect product water from Last-stage post carbon filter output to dispensing faucet- 3/8”
Clear tubing.
Drain line to W: Connect waste water line from the RO to drain outlet- 1/4” Black tubing.
* How Tank line works: The line from Point G to Y works as a 2-way line; the Product water enters and
leaves the tank via this same line.
Fig. 6
Make the tubing connections as follows:
To ensure a smooth and correct installation, please connect the water lines in the order outlined below.
Refer to Fig.6 for proper point locations.
Pure Water
Output Faucet
Sample Kitchen
Faucet
Drain Line
Tank Ball Valve
Feed Water
Connect on
Cold Water Line
Drain Saddle
Sample Drain Pipe
Pure Water
Holding Tank
G
Y
H
Z
X
A
W
W
ate
r
F
aucet