CONCERN I POTENTIAL CAUSE j COHHON SOLUTION
RUNNING OF REFRIGERATOR
* Set freezer control.
Compressor does not * Freezer control is set to "OF"
run. or "0".
Refrigerator is in defrost cycle.
Plug at electrical outlet is dis-
connected.
House fuse blown or tripped
circuit breaker.
Power outage.
Refrigerator runs too * Room or outside weather is
much or too long. hot.
Doors are opened too frequent-
ly or too long.
- Fresh Food/freezer door may
be slightly open.
Freezer control is set too cold.
- Fresh Food/freezer gasket is
dirty, worn, cracked, or poorly
fitted.
Condenser is dirty.
Compressor goes off Thermostat keeps the refrigera-
and on frequently, tor at a constant temperature.
This is normal for a fully automatic defrost refrigerator.
The defrost cycle occurs periodically, lasting about 30
minutes.
Ensure plug is tightly pushed into outlet.
Check/replace fuse with a 15 amp time-delay fuse. Reset
circuit breaker.
Check house lights. Call local electric company.
=
It's normal for the refrigerator to work longer under these
conditions.
Warm air entering the refrigerator causes it to run more.
Open doors less often.
Ensure refrigerator is level. Keep food and contains from
blocking door. See CONCERN column OPENING/CLOSING
OF DOORS/DRAWERS.
Set Fresh Food control to warmer setting until refrigerator
temperature is satisfactory. Allow 24 hours for tempera-
ture to stabilize.
Clean or change gasket. Leaks in door seal will cause
refrigerator to run longer in order to maintain desired
temperatures,
Clean condenser. See Care & Cleaning.
This is normal. Refrigerator goes on and off to keep tem-
perature constant.
DIGITAL TEHPERATURE DISPLAY
Digital temperature [ Electronic control system has * Call your Frigidaire service representative, who can inter-
displays are flashing. _ detected a performance prob- pret any messages or number codes flashing on the digital
lem. displays.
WATER DISPENSER
Dispenser will not dis=
pense water.
__ m
Water has an odd taste
and/or odor.
Household water line valve is
not open.
Tceand water filter cartridge is
clogged.
Filter not fully installed.
' water haS been in the tank for
a period of timel
, Unit not propedy connected to
cold water line.
Open household water line valve. See CONCERN column
AUTOMATIC TCE HAKER.
Replace filter cartridge.
Push filter in until you hear a "click':
Draw and discard 10.12 glasses of water to freshen the
supply and completely rinse out the tank.
Connect unit to cold waterline that supplies water to the
kitchen faucet.
Water pressure is ex= Cut-off and cut-on pressures Have someone turn up the cut-off and cut-on pressure on
tremely low. are too low (well systems only), the water pump system (well systems only).
Reverse osmosis system is in Tt is normal for a reverse osmosis system to be below 20
regenerative phase, psi during the regenerative phase.
WATER/HOISTURE/FROST INSIDE REFRIGERATOR
Moisture collects on Weather is hot and humid. The rate of frost buildup and internal sweating increases.
inside of refrigerator Door is slightly open. * See CONCERN column OPENTNG/CLOSING OF
walls. DOORS/DRAWERS.
Water collects on bot- vegetables contain andgive off ' iS not unusual to have moisture on the bottom side of
tom side of drawer m()isture, the cover.
cover. ' .............. Move humidity control (some models) to lower setting: ..........
Water collects in bot= * Washed vegetables and fruit * Dry items before putting them in the drawer. Water col-
tom of drawer, drain while in the drawer, lecting in bottom of drawer is normal.
WATER/HOISTURE/FROST OUTSIDE REFRIGERATOR
Moisture collects on Weather is humid. * This is normal in humid weather. When humidity is lower,
outside of refrigerator the moisture should disappear.
or between doors. * Door is slightly open, causing * See CONCERN column OPENING/CLOSING OF
cold air from inside refrigerator DOORS/DRAWERS.
to meet warm air from outside.
Loading ...