Model#5000 BTU


INTRODUCTION
IMPORTANT SAFETY INSTRUCTION ............................................................................
ELECTRICAL REQUIREMENTS ....................................................................................
PACKING LIST .............................................................................................................
INSTALLATION&ASSEMBLY INSTRUCTIONS ................................................................
USING YOUR AIR CONDITIONER ..................................................................................
CARE AND CLEANING ................................................................................................ .
TROUBLESHOOTING ...................................................................................................
1
3
4
5
10
11
12

1
FCC ĂƵƟŽŶ.
This device ĐŽŵƉůŝĞs with ƉĂƌƚ 15 Žf the FCC ZƵůĞƐ. KƉĞƌĂƟŽŶ is subject ƚŽ the ĨŽůůŽǁŝŶŐ twŽ
ĐŽŶĚŝƟŽŶƐ (1) This device ŵĂLJ ŶŽt cause ŚĂƌŵĨƵů ŝŶtĞƌĨĞƌĞŶĐĞ ĂŶd (2) this device ŵƵst ĂĐĐĞƉt
ĂŶLJ ŝŶƚĞƌfĞƌĞŶĐĞ ƌĞĐĞŝǀĞĚ ŝŶĐůƵĚŝŶŐ ŝŶƚĞƌĨĞƌĞŶĐe that ŵĂLJ cause ƵŶĚĞƐŝƌĞĚ ŽƉĞƌaƟŽŶ.
ŶLJ ŚĂŶŐĞƐ Žƌ ŵŽĚŝĮĐĂƟŽŶƐ ŶŽƚ edžƉƌĞƐƐůLJ ĂƉƉƌŽǀĞd ďLJ the ƉĂƌƚLJ ƌĞƐƉŽŶƐŝďůĞ ĨŽƌ ĐŽŵƉůŝĂŶĐe
ĐŽƵůĚ ǀŽŝĚ the ƵƐĞƌΖƐ ĂƵƚŚŽƌŝƚLJ tŽ ŽƉĞƌĂƚĞ the ĞƋƵŝƉŵĞŶƚ.

2
INTRODUCTION TO REFRIGERANTS R32
9K
12K
18K
24K
The refrigerants used for air conditioners are environmentally friendly hydrocarbons R32. This kind of erant is
combustible and odorless. Moreover, it can burn and explode und
er certain condition. However, there will be no
risk of burning and explosion if you comply with the following
table to install your air conditioner in a room with
an appropriate area and use it correctly.
Compared with ordinary refrigerants, Refrigerant R32 is environmentally friendly and do not destroy the ozone
sphere and that its value of greenhouse effect is also very low.
Room area requests for air conditioner with Refrigerant R32
Warnings
Please read the manual before installation, using, maintenance.
Do not use means to accelerate the defrosting process or to clean, other than those recommended by the
manufacturer.
Do not pierce or burn the appliance.
The appliance shall be stored in a room without continuously operating sources (for example: open flames,
an operating ignition gas appliance or an operating electric heater.)
Please contact the nearest after-sale service center when maintenance is necessary. At the time of
maintenance, the maintenance personnel must strictly comply with the Operation Manual provided by the
corresponding manufacturer and any non-professional is prohibited to maintain the air conditioner.
The handling, installation, storage, servicing and disposal must comply with the provisions of gas-related
national laws and regulations, and also national wiring regulation.
It is necessary to clear away the refrigerant in the system when maintaining or scrapping an air conditioner.
Be aware that refrigerants may not contain an odour.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or
mental capabilities, or supervision or instruction concerning use of the appliance by a person responsible for
their safety.
Children should be supervised to ensure that they do not play with the appliance.
Unit operation limits: Outdoor side 61~110, 80%RH; indoor side 61~90, 80%RH.
R32
Refrigerant
Capacity(Btu)
Room Area
2
Above 4m
2
Above 4m
2
Above 15m
2
Above 25m

3
7
8

4
Crosley Corporation

5
23" to 36"
584 mm to 914 mm
14 1/2" min
(368mm)
OFFSET
STOOL
SILL
INTERIOR
WALL
EXTERIOR
WALL
FIG. 1
684

6
(Suggest to keep a downward
oblique, to let accumulated rain water to drain out,
from back side of the unit bottom.)
8
5
76

7
FIG. 9
9
10
FIG. 10
FIG. 11FIG. 12
FIG. 13
FIG. 14
4

8
INSTALLATION & ASSEMBLY INSTRUCTIONS
Introduction to Refrigerants R32
1. Site Safety
2. Operation Safety
Open Flames ProhibitedVentilation Necessary
Open Flames Prohibited
Mind Static ElectricityMust Wear Protective Clothing and anti-static gloves
Don't use mobile phone
3. Installation Safety
Refrigerant Leak Detector
Appropriate Installation Location
The left picture is the schematic diagram of a refrigerant leak detector.
Please note that:
1. The installation site should be in a well-ventilated condition.
2. The sites for installing and maintaining an air conditioner using Refrigerant R32 should be free from open fire
or welding, smoking, drying oven or any other heat source higher than 548 which easily produces open fire.
3. When installing an air conditioner, it is necessary to take appropriate anti-static measures such as wear anti-
static clothing and/or gloves.
4. It is necessary to choose the site convenient for installati
on or maintenance wherein the air inlets and outlets of
the indoor and outdoor units should be not surrounded by ob
stacles or close to any heat source or combustible
and/or explosive environment.
5. If the indoor unit suffers refrigerant leak during the insta
llation, all the personnel should go out till the refrigerant
leaks completely for 15 minutes. If the product is damaged,
it is a must to carry such damaged product back to
the maintenance station and it is prohibited to weld the re
frigerant pipe or conduct other operations on the user's
site.
6. It is necessary to choose the place where the inlet and outlet air of the indoor unit is even.
7. It is necessary to avoid the places where there are other electrical products, power switch plugs and sockets,
kitchen cabinet, bed, sofa and other valuables right under the lines on two sides of the indoor unit, and also
prevent mechanical damage from occurring.

9
To direct the airflow,
horizontal wheel to control the horizontal
direction, air deflector to control the vertical
direction.
horizontal wheelair deflectorair deflector

10
FIG. 15
15

11