Frigidaire LGQ6000ES0 dryer

User Manual - Page 8

For LGQ6000ES0.

PDF File Manual, 15 pages, Download pdf file

Loading ...
Loading ...
Loading ...
ELECTRICAL CONNECTIONS FOR 4-W/RE SYSTEM
I NONoCANAD/AN ELECTR/C Dryer
1. Rernov_ th_ screws securing th_ terminal block access cover and
the strain relief mounting bracket located on the back of the dryer
upper corner,
2. Install a U.L, approved strain relief in the entry hole of the mounting
bracket, Finger tighten the nut only at this time.
3. Remove the ground wire from the green ground screw located
above the terminal block.
GREEN POWER CORD
GREEN GROUND WIRE
SILVERTERMINAL
SCREW TERMINAL
BLOCK
BLACK TIGHTEN
NUT
GROUND WHITE TO THESE
WIRE HREADS
STRAIN\
RELIEF "
BRACKET.
>OWER
CORD
4. Thread a U.L. approved 30 amp power cord, NEMA 14-30 type ST or
SRDTthrough the strain relief.
TYPICAL 4 BLACK
CONDUCTOR TYPICAL 4
CONDUCTOR WHITE
_ ,_P_ED
30 AMP NEMA 14o30 TYPE SRDT OR BT "_GREEN
Attach tile green power cord ground wire to the cabinet with the
green ground screw,
Attach the white (neutral) power cord conductor from the power
cord and the neutral ground wire from the dryer harness to the
silver-colored center terminal on the terminal block. Tighten the
screw securely.
Attach the red and black power cord conductors to the outer
brass<olored terminals on the terminal block,
Do not make a sharp bend or crimp wiring/conductor
at the connections,
8. Tighten the screws securing the cord restraint firmly against the
power cord.
9, Tighten the strain relief nut securely so the strain relief does not
turn,
10, Reinstall the terminal block access cover.
GAS CONNECTION
Remove the shipping cap from gas pipe at the r_,ar of th_ dryer.
NOTE: DO NOT connect the dryer to L.R gas service without
converting the gas valve. An L,R conversion kit must be installed
by a qualified gas technician,
Connect a 1/2 inch (1,27 cm) I.D. semi-rigid or approved pipe from
gas supply line to the 3/8 inch (0.96 cm) pipe located on the back
of the dryer (see pages 6 and 7). Use a I/2 inch to :V8 inch (1,27
cm to 0.96 cm) reducer for a connection. Apply an approved
thread sealer that is resistant to the corrosive action of liquefied
gases on all pipe connections,
_-_ VALVE OPEN / GAS FLOW POSITION
4. lest all connections by brushing on a soapy water solution. NEVER
test for gas leaks with an open flame.
GENERAL INSTALLATION
1. Cennect the exhaust duct to outside exhaust syst_,m (see pages 3
and 4). Use duct tape to seal all joints,
With the dryer in its final position, adjust one or more of the legs
until the dryer is resting solid on all four legs Place a level on top
of the dryer, The dryer MUST be level and resting sofid on aft
four legs.
3. Plug the power cord into a grounded outlet. NOTE: Check to
ensure the power is off at circuit breaker/fuse box before plugging
the power cord into the outlet.
Turn on the power at the circuit breaker/Iuse box.
Before operating the dryer, make sure the
dryer area is clear and free from combustible materials,
gasoline, and other flammable vapors. Also see that
nothing (such as boxes, clothing, etc.) obstructs the flow
of combustion and ventilation air.
Run the dryer through a cycle check for proper operation.
NOTE: On gas dryers, bolero the burner will light, it is necessary
for the gas line to be bled of air. If the burner does not light within
45 seconds the first time the dryer is turned on, the safety switch
will shut the burner off. if this happens, turn the timer to "OFF" and
wait Bminutes before making another attempt to light,
6. If your dryer does not operate, please review the "Avoid Service
Checklist" located in your Use and Care Guide before calling for
service,
Place these instructions in a location near the dryer for future
reference.
NOTE; A wiring diagram/tech sheet is in an envelope attached to
the inside side panel of the dryer by the blower housing,
Pedestal
A pedestal accessory, Model No. APWD15W, specifically designed
for this dryer may be used when elevating the dryer for ease of use,
Failure to use accessories certified by the manufacturer could result
in personal injury, property damage or damage to the dryer,
REPLA CEMENT PARTS
If replacements parts are needed for your dryer, contact the source
where you purchased your dryer, call 1-800-944-9044, or visit our
website, www.frigidaire.com, for the Frigidaire Company Authorized
Parts Distributor nearest you.
Label all wires prior to disconnection when servicing
controls. Wiring errors can cause improper and dangerous operation.
Verify proper operation after servicing
Destroy the carton and plastic bags after the dryer is
unpacked, Children might use them for play, Cartons covered with
rugs, bedspreads, or plastic sheets can become airtight chambers
causing suffocation, Place all materials in a garbage container or make
materials inaccessible to children.
The instructions in this manual and all other literature
included with this dryer are not meant to cover every possible
condition arid situation that may occur. Good safe practice and caution
MUST be applied when installing, operating arid maintaining any
appliance,
3. Open the shutoff valve in the gassupply line to allow gas to flow
through the pipe.
8
Loading ...
Loading ...
Loading ...