USER GUIDE
Control Operation - Service 6
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Evap Fan (excludes ZWC)
The Evap Fan option in the service menu allows servicers
to change the Evaporator Fan runtime (in minutes) from 0
to 98 and OFF cycle time 0 to 98.
To access Evap Fan
1. Press to select “Evap Fan.
2. Press .
3. Press and to scroll through available settings.
To exit the Evap Fan menu, press to select “Return to
Menu” and press to confirm.
Mullion (Drawer Models)
The Mullion (MULL) option in the service menu allows
servicers to change the ON/OFF time in minutes of the
MULL heater (DWR only) from 0 to 98.
To access Mullion
1. Press to select “MULL.
2. Press .
3. Press and to scroll through available settings.
To exit the MULL menu, press to select “Return to
Menu” and press to confirm.
Factory Default
Factory Default will restore all settings to their factory
default.
To access Factory Default
1. Press to selectFactory Default.
2. Press .
To restore settings to their factory default.
3. Press to select “Restore?” and press
4. Restore?” will change to “Restoring... while settings
are restored. When restoration is complete,
Restoring... will return to Restore?”.
To exit Factory Default, press to select “Return to
Menu” and press to confirm.
Re-Select Model
NOTICE
Before altering model selection U-Line customer
service must be notified. Failure to notify
customer service will result in voiding of the
manufacturer warranty.
Up
Select
Down
RETURN TO MENU
EVAP FAN
EVAP FAN ON = 1
EVAP FAN OFF = 60
Up
Select
Down
RETURN TO MENU
MULL
MULL ON = 5
MULL OFF = 30
Up
Select
Down
RETURN TO MENU
FACTORY DEFAULT
RESTORE?
Up
Select
Down
RETURN TO MENU
RE-SELECT MODEL #
3018R