USER GUIDE
Defrost
Defrost
This unit defrosts, by default, every 12 hours of compressor runtime for 45 minutes. If you have veried that
the unit does not have an ambient air leak, refer to the Control Operation - Service section and adjust unit to
defrost every 9 hours for 60 minutes. Also, adjust the #2 thermistor to -4 instead of 0.