OM-40MAQ-07 Specifications subject to change without notice. 9
FOLLOW ME Mode
Press FOLLOW to activate or deactivate this function. Under this
setting, the temperature that appears in the remote control is the actual
temperature at its location. The remote control sends this signal to the
air conditioner every 3 minutes. This function is not available in the
DRY and FAN modes. This function can also be deactivated if:
1. No FOLLOW ME signal is received by the unit for continuous 7
min
2. Users adjust the operation mode
3. Users turn off the unit
4. Users turn off the FOLLOW ME function
NOTE: If FOLLOW ME is used with the wireless remote controller,
make sure that the remote’s IR sender is within line of sight of the IR
receiver of the unit and is within the maximum range of 25 feet of the
indoor unit. If FOLLOW ME is de-activated by pressing MODE,
OFF or FOLLOW ME on the remote, the icon on the remote will
turn off.
Freeze Protection (FP) Mode
Press
FP
for approximately 2 seconds to activate or deactivate the
freeze protection mode (heating set back). The indoor unit displays
FP.
NOTE: This function is only available in the heating mode.
Under this function, the unit operates at high fan speed and the coil
temperature automatically sets to 46°F (8°C). This mode can also be
deactivated by pressing ON/OFF, SLEEP, MODE, FAN, or either
TEMP.
SILENCE Mode
Press SLC to activate of deactivate the SILENCE Mode. Under this
function, the compressor operates at low frequency and the indoor
unit produces a faint breeze, which reduces the noise to the lowest
level. Due to low the frequency operation of the compressor, it may
result in insufficient cooling and heating capacity.
LED Light
Press LED to turn the display light on and off.
Resetting the Remote Control
If the batteries in the remote control are removed, the current settings
will be canceled and the control returns to the initial settings and
enters the STANDBY mode. Push ON/OFF to activate.
Time Delay
If ON/OFF is pressed too soon after a stop, the compressor will not
start for 3 to 4 minutes due to the inherent protection against frequent
compressor cycling. The unit only emits an audible beep when the
signals are received correctly.
Heating Features
If the unit is in HEATING mode, there is a delay when the fan starts.
The fan starts only after the coil is warmed up to prevent cold blow.
Auto Defrost Operation
In the HEATING mode, if the outdoor coil is frosted, the indoor fan
and outdoor fan turns off while the system removes the frost on the
outdoor coil. The system automatically reverts to normal operation
when frost is removed from the outdoor unit.
Auto Start
If the power fails while the unit is operating, the unit stores the
operating condition, and it will start operation automatically under
those conditions when the power is restored.
Refrigerant Leakage Detection
The indoor unit displays EC and the indication lamps continue
flashing when it detects a refrigerant leak.