Shaking during transportation can cause valve to be open. if
this occurs, water may run continuously through the valve
during installation.
Turn the water off. Remove the batteries. Wait for the screen to
go blank. Reinsert the batteries. Turn the water back on.
Note: Removing the batteries will not erase any existing
watering schedules.
If the problem persists, turn off the water. Use the Manual
feature to open and close the valve 3 times.
This device complies with Industry Canada’s licence-exempt RSSs.
Operation is subject to the following two conditions:
( 1 ) This device may not cause interference; and ( 2 ) This device
must accept any interference, including interference that may cause
undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada
applicables aux appareils radio exempts de licence. L'exploitation est
autorisée aux deux conditions suivantes : ( 1 ) l'appareil ne doit pas
produire de brouillage, et ( 2 ) l'utilisateur de l'appareil doit accepter
tout brouillage radioélectrique subi, même si le brouillage est
susceptible d'en compromettre le fonctionnement
Useful Tips:
FCC Statement:
CAN ICES-3 (B)/NMB-3(B) Canada Statement :
Open Valve During Installation:
Freezing temperatures can cause water in the timer to freeze
and expand, damaging the timer. At the end of the season or
when there is frost in the forecast, turn off the water and
remove your timer from the faucet.
Remove the batteries.
Be sure to store the timer indoors, away from freezing
temperatures.
Seasonal Storage:
- Make sure to use fresh alkaline batteries.
- Do not use rechargeable batteries.
- Remove the batteries at the end of the season before storing.
- Batteries should last about one season. A schedule with
more frequent watering times can cause the batteries to drain faster.
Tips for Battery Life:
You should clean your timer periodically. Debris or sediments
commonly found in water can build up in your timer.
Turn off the water. Remove the timer from the faucet and
check that the filter washer is clear. If you notice any debris,
remove the filter washer and clean it out with water.
Activate the MANUAL mode by pressing the MANUAL
button. Open the valve and spray water through the valve and
the faucet connection to flush out any built-up sediments or
debris.
This device complies with part 15 of the FCC Rules. Operation is
subject to the following two conditions:
( 1 ) This device may not cause harmful interference, and ( 2 ) this
device must accept any interference received, including interference
that may cause undesired operation.
Caution: Any changes or modifications not expressly approved by the
grantee of this device could void the user’s authority to operate the
device.
Note: This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or
more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Cleaning Your Timer:
Should your unit need replacement after extended use, do not dispose of it with the household waste, but in an environmentally safe way.
Waste produced by electrical machine items should not be handled like normal household garbage. Please recycle where recycle
facilities exist. Check with your local authority or retailer for recycling advice.
Disposal:
Intended for outdoor use only. Severe electrical shock could result if water is sprayed into outlets or sources of electrical current. Do not use water
more than 115°F (46°C). Do not use when the ambient air temperature is less 40°F (4.5°C). When not in use, remove batteries, drain and store
indoors away from freezing temperatures.
CAUTION
!!
PLANNING TABLE
ZONE 1
Start Water (Time)
How Long (Minutes)
Start Water (Time)
How Long (Minutes)
CYCLE A CYCLE B CYCLE C CYCLE D
ZONE 2 CYCLE A CYCLE B CYCLE C CYCLE D
ZONE 3
Start Water (Time)
How Long (Minutes)
Start Water (Time)
How Long (Minutes)
CYCLE A CYCLE B CYCLE C CYCLE D
ZONE 4 CYCLE A CYCLE B CYCLE C CYCLE D
Prevent overwatering while conserving water
by connecting your timer to the Wireless Soil
Moisture Sensor. The easy to set sensor
monitors moisture in the soil, and will
suspend a watering cycle when it is raining or
when the ground is already wet.
Works with
Wireless Soil Moisture Sensor (not included)
Learn more at www.edengarden.com
1.
2.
Filter
RAIN DELAY, HOLD
WATER DAY START WATER
HOW LONG
OFF
SENSOR
SET TIME
AUTO
RAIN DELAY, HOLD
WATER DAY START WATER
HOW LONG
OFF
SENSOR
SET TIME
AUTO
CYCLE
MIN
MANUAL
PM
TODAY
DELAY
TIME
WATER EVERY
SU
FR
SA
TH
WE
TU
MO
A
B
C
D
DAY
NEXT START
ZONE
AM
HRS
DAY
1
2
3
4
SENSOR
RESET
RAIN DELAY, HOLD
WATER DAY START WATER
HOW LONG
OFF
SENSOR
SET TIME
AUTO
CYCLE
MIN
MANUAL
PM
TODAY
DELAY
TIME
WATER EVERY
SU
FR
SA
TH
WE
TU
MO
A
B
C
D
DAY
NEXT START
ZONE
AM
HRS
DAY
1
2
3
4
SENSOR
RESET
Valve
Faucet
connection
WARNING: This product can expose you to chemicals including lead, which is known to the State of California to
cause cancer and birth defects or other reproductive harm, and styrene, which is known to the State of California to cause
cancer. For more information go to www.P65Warnings.ca.gov.
!
Loading ...