Loading ...
Loading ...
Loading ...
Installation
*INSTALLATION*
59
Ventilation
The cool air intake at the front of the
tumble dryer must not be blocked or
covered. This would hinder a suffi-
cient intake of cool air for the heat
exchanger.
Do not block the gap between the
bottom of the tumble dryer and the
floor with plinth facings, deep pile
carpet etc. This would hinder a suffi-
cient flow of air to the tumble dryer.
The hot air that is blown out from the
heat exchanger warms the room air. En-
sure sufficient ventilation of the room:
e.g., open the window. The drying time
will otherwise take longer (higher energy
requirement).
The heat pump that is essential to
the operation of this tumble dryer
generates a great deal of heat inside
its casing. There must be a reliable
means of dissipating this heat.
Otherwise loads could take longer to
dry or the tumble dryer might sustain
damage in the long term.
Permanent room ventilation during
every drying programme and the gap
between the bottom of the tumble
dryer and the floor are mandatory re-
quirements at all times.
Before moving the tumble dryer
again
A small quantity of condensed water
that remains in the area around the
pump after the drying process can run
out if the tumble dryer is tilted. Recom-
mendation: start a programme for ap-
prox. 1minute before transporting the
dryer. Any remaining condensed water
will then be fed into the condensed wa-
ter container (which you will need to
empty again) or out through the drain
hose.
Loading ...
Loading ...
Loading ...