5
INSTALLATION
window
slider
hose
outlet
hose hose
inlet
ASSEMBLY OF EXHAUST HOSE, HOSE INLET, HOSE OUTLET AND WINDOW SLIDER
Fully extend each end of the exhaust hose by about 10cm and attach the hose inlet and hose outlet to
opposite ends by rotating the inlet/outlet in a counter clockwise direction approximately 3 to 4 turns, making
sure that the hose wire is well threaded into the hose inlet and outlet. The hose inlet and outlet cannot be
installed unless the hose ends have been fully extended.
Clip the hose outlet into the window slider. Take care to not break the tabs on the hose outlet when
disconnecting from the window slider.
SELECTION OF INSTALLATION LOCATION
Place the portable air conditioner in a flat location where the air inlets and outlets cannot be covered up. Place
the unit no less than 50cm away from a wall or other obstacle. In addition, a minimum 50cm clearance is required
from all faces of the air conditioner including the rear face.
50cm
50cm
50cm
50cm