Napoleon GX70PTE Ascent X 70 Series Direct Vent Liquid Propane Fireplace

User Manual - Page 24

For GX70PTE.

PDF File Manual, 112 pages, Read Online | Download pdf file

GX70PTE photo
Loading ...
Loading ...
Loading ...
24
W415-1519 / G / 11.03.16
EN
!
WARNING
1. MOST RESTRICTION
2. MODERATE RESTRICTION
3. LEAST RESTRICTION
EXHAUST COLLAR
RESTRICTOR
MOUNTING
SCREWS
FIREBOX TOP
FIREBOX TOP
RESTRICTOR
TOP VIEW
#8 x ½ HEX HEAD
SHEET METAL
SCREW
TURN OFF GAS AND ELECTRICAL SUPPLY BEFORE SERVICING THE APPLIANCE.
APPLIANCE MAY BE HOT, DO NOT SERVICE UNTIL APPLIANCE IS COOL.
FOR SAFE AND PROPER OPERATION OF THE APPLIANCE, FOLLOW THE VENTING INSTRUCTION EXACTLY.
TO AVOID DANGER OF SUFFOCATION KEEP THE PACKAGING BAG AWAY FROM BABIES AND
CHILDREN. DO NOT USE IN CRIBS, BED, CARRIAGES OR PLAY PENS. THIS BAG IS NOT A TOY.
KNOT BEFORE THROWING AWAY.
Vertical installations may display a very active fl ame. If this appearance is not desirable, the exhaust outlet may
be restricted with a Wolf Steel approved restrictor kit. This kit is not recommended for short vertical vent runs.
Depending on the model and/or year of your appliance, mounting holes may not exist.
A. If mounting holes exist, remove the screws from the fi rebox top, align the restrictor plate as illustrated
and secure.
B. If mounting holes do not exist, align the restrictor plate as illustrated and secure using the two #8x1/2
hex head sheet metal screws supplied.
C. Ensure the plate will pivot at the slot up into the exhaust outlet.
D. Depending on the amount of restriction desired, the restrictor plate can be left fl at for most restriction or
bent up for varying degrees of restriction.
4.3 RESTRICTING VERTICAL VENTS
Loading ...
Loading ...
Loading ...