AirWash Whisper Manual 2019_1
Independent Operation:
The HEPA system can be used independently of any other equipment! The intake and outflow of the filtration
system can be ducted into the same room to create a cleaner environment almost anywhere. The intake or outflow
can also be ducted elsewhere. The intake and outflow should be installed on opposite sides of the room; however,
this varies according to your specific needs.
Preparation:
Here are some things to consider as you
decide where to install the HEPA system
independently of other systems.
Location:
• Make sure there is room to open the
HEPA filter access panel for filter
changes/inspections.
• Keep the HEPA system away from
possible water damage.
• Vibration pads will reduce vibration for
installations where the unit is placed on
the floor.
• Install HEPA system on floor
or suspended platform. If the unit
is suspended, screws must not
penetrate through the cabinet. Make
sure that you have the proper chains/straps/joists and
equipment to keep unit secure.
Intake0DUNHGDVµ$LU,Q¶RQXQLW
• Intake ducts should be installed near the floor for
optimum airflow. If space does not allow, then the inlet
can be installed in the ceiling.
• Intake duct should be installed at least 6 ft. away from
the outflow duct.
• Intake duct should be installed at opposite end of the
room from the outflow duct(s) if in the same room.
• Diffusers are recommended to help distribute airflow
evenly.
Outflow0DUNHGDVµ&OHDQ$LU2XW¶RQXQLW
• Outflow(s) should be installed in the ceiling away from
any other air inlet(s).
• Room diffusers are recommended to help distribute
airflow evenly in the occupied space.
Ducting:
,I+(3$V\VWHPLVLQVWDOOHGZKHUHLQOHWDQGRXWÀRZ
collars face down, metal elbows must be connected to
ERWKLQOHWDQGRXWÀRZFROODUV
• Each connection must be sealed with aluminum tape or
mastic, including all vent connections.
• Installed duct runs should be as straight as possible (if
the duct runs are too long, reduced CFM may result).
,IGXFWLVH[SRVHGWRXQFRQGLWLRQHGDLULQVXODWHGÀH[
duct is highly recommended.
([WHUQDOO\LQVXODWHGÀH[GXFWFDQDOVREHXVHGIRUQRLVH
reduction purposes.
• For best indoor air quality, do not use ductboard or
¿EHUJODVVLQVLGHRIGXFWV
Electricity:
• The unit must be plugged into a grounded 120V, 60Hz.
outlet.
Required Materials for Installation of Unit:
Items for AWW-350
Flex or rigid duct 8” round & 6” round
(length as required)
Takeoffs One 8” & One 6”
Diffusers One 8” & One 6”
Items for AWW-675
Flex or rigid duct 10” round & 8” round
(length as required)
Takeoffs One 10” & One 8”
Diffusers One 10” & One 8”
All Models
Aluminum tape or mastic as required
0LVFKDQJLQJPDWHULDOV¿HOGSURYLGHG
NOTE: Be sure to review ‘Rules for Safe Installation and
Operation’ on page 1 of this document
before start-up of this unit.
Dealer Installation Instructions
Example of Single Room Stand Alone System Installation
For single rooms where increased filtration is desired such as a
dedicated “smoking room”.
Air should be drawn from
location B if space is
available, otherwise use
location A.
Figure 9
A
B
HEPA System
8